2015
DOI: 10.1001/jamaophthalmol.2015.0429
|View full text |Cite
|
Sign up to set email alerts
|

Variability of Tear Osmolarity in Patients With Dry Eye

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

2
49
1
1

Year Published

2015
2015
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 76 publications
(55 citation statements)
references
References 25 publications
2
49
1
1
Order By: Relevance
“…It would be expected that those participants with high osmolarity readings using the lubricant eye drop in this study containing a hypo-osmolarity component would have decreased osmolarity over time. A previous study showed that higher variability was attributed to blepharitis and Sjögren's syndrome dry eye compared to normals 35 . In our study, we had found that the standard deviations in our osmolarity measurements remained similar over time (12.6 at baseline, 11.1 at 1 month, 11.1 at 3 months) even though we observed improvements in many other areas (e.g.…”
Section: Discussionsupporting
confidence: 54%
“…It would be expected that those participants with high osmolarity readings using the lubricant eye drop in this study containing a hypo-osmolarity component would have decreased osmolarity over time. A previous study showed that higher variability was attributed to blepharitis and Sjögren's syndrome dry eye compared to normals 35 . In our study, we had found that the standard deviations in our osmolarity measurements remained similar over time (12.6 at baseline, 11.1 at 1 month, 11.1 at 3 months) even though we observed improvements in many other areas (e.g.…”
Section: Discussionsupporting
confidence: 54%
“…Extensive clinical and basic research on tear osmolarity in humans found a wide range of osmolarities in normal (approximately 290–330 mOsm/L 12,13 ) and DE patients (approximately 315–365 mOsm/L 3134 ), even 675 mOsm/L in one study. 35 Many factors, such as the measurement system used (freezing point to TearLab Corporation), repeated measurements, 13 and the time of day, and even changes within an individual, such as intereyes differences and environmental disparities, 36 are thought to contribute to these variabilities.…”
Section: Discussionmentioning
confidence: 91%
“…36 Clinical and methodologic issues associated with the tear measurement systems have been raised recently by many investigators. 12,13,3739 These do not, however, invalidate the importance of tear hyperosmolarity to the pathophysiology of DED. 38 …”
Section: Discussionmentioning
confidence: 96%
See 2 more Smart Citations