2020
DOI: 10.1148/ryct.2020190090
|View full text |Cite
|
Sign up to set email alerts
|

Variability of MRI Aortic Stiffness Measurements in a Multicenter Clinical Trial Setting: Intraobserver, Interobserver, and Intracenter Variability of Pulse Wave Velocity and Aortic Strain Measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 25 publications
0
5
0
1
Order By: Relevance
“…[ 23 ] However, the disadvantages of this method include that its methodology has not yet been standardized,[ 22 ] it is expensive, not easily accessible,[ 24 ] and the variability in MRI aortic stiffness measurements. [ 25 ]…”
Section: Discussionmentioning
confidence: 99%
“…[ 23 ] However, the disadvantages of this method include that its methodology has not yet been standardized,[ 22 ] it is expensive, not easily accessible,[ 24 ] and the variability in MRI aortic stiffness measurements. [ 25 ]…”
Section: Discussionmentioning
confidence: 99%
“…Biomarkers of longitudinal and circumferential deformation have been shown to be inversely related to PWV. 6 , 14 , 63 , 66 , 67 By MRI, intra‐ and interobserver reproducibility were acceptable 28 or high, 63 , 64 , 66 and scan‐rescan acceptable 28 for distensibility in the thoracic aorta as well as for longitudinal deformation of the proximal aorta. 11 Given the similarity in assessment, these results should translate to circumferential strain assessment as well.…”
Section: Biomarkers Of Aortic Agingmentioning
confidence: 90%
“…Many studies tested intra‐ and inter‐observer reproducibility and mostly reported good‐to‐excellent results. Reproducibility tests are available for Fourier‐encoded data, 3 , 22 2D PC with both in‐ and through‐plane velocity encoding 2 , 4 , 8 , 9 , 13 , 25 , 28 and for 4D flow. 14 , 19 , 20 , 29 Scan‐rescan (ie, test–retest, inter‐scan) reproducibility was good or moderate by 2D PC, 13 , 28 4D flow 20 and Fourier‐encoded data.…”
Section: Biomarkers Of Aortic Agingmentioning
confidence: 99%
See 1 more Smart Citation
“…Despite all the advantages, ultrasound-based PWV measurements also entail some detrimental characteristics like the error-prone distance measurements [ 109 ]. Therefore—especially in comparison to MRI—ultrasound is very user-dependent [ 110 ]. In addition, ultrasound has a limited penetration depth, making some vessels difficult to reach.…”
Section: Arterial Wall Stiffness In Atherosclerosismentioning
confidence: 99%