1994
DOI: 10.2172/10193497
|View full text |Cite
|
Sign up to set email alerts
|

Vapor space characterization of Waste Tank 241-C-103: Inorganic results from sample Job 7B (May 12-25, 1994)

Abstract: Samples of vapor obtained in May 1994 from the headspace of the Hanford single-shell waste storage tank 24 1-C-103 were analyzed for selected inorganic compounds at Pacific Northwest Laboratory. The work was performed to provide concentration information supporting safety and toxicological evaluations. The vapor samples were passed through analyte-specific solid sorbent traps which held the compounds by chernisorption until analysis. Samples were analyzed to determine the concentrations of ammonia, nitric oxid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
142
0

Year Published

1994
1994
1995
1995

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(142 citation statements)
references
References 1 publication
0
142
0
Order By: Relevance
“…Inorganic sampling and analysis methods followed those described by Ligotke et al (1994) for samples obtained fiom C-103, a tank containing a relatively complex headspace composition. Method-validation measurements during that study did appear to validate the trapping analysis of NH3, but did not eliminate the possibility of interferences that could affect NO, results.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Inorganic sampling and analysis methods followed those described by Ligotke et al (1994) for samples obtained fiom C-103, a tank containing a relatively complex headspace composition. Method-validation measurements during that study did appear to validate the trapping analysis of NH3, but did not eliminate the possibility of interferences that could affect NO, results.…”
Section: Discussionmentioning
confidence: 99%
“…Nitrite blank levels used to correct data were 0.0158 f 0.0002 pmol in front and 0.0075 k 0.0003 pmol in back sorbent sections and were based on three blanks. Although spiked blanks were not tested, blanks spiked with 0.0064, 0.047, 0.11, and 0.74 pmol NO; during related sample jobs yielded percentage recoveries of 153 k 14%, 103 f 4%, 106 8%, and 111 f 7%, respectively (Clauss et al 1994;Ligotke et al 1994). No samples were reanalyzed to check repeatability.…”
Section: )mentioning
confidence: 99%
“…Although spiked blanks were not tested, the percentage recoveries of three sets of blanks spiked with 12.2, 22.3, and 46.4 pmol of NH, were 101 & 4%, 109 k 2%, and 104 f 1 %, respectively, during related sample jobs (Clauss et al 1994;Ligotke et al 1994). The analyses of two samples were duplicated and yielded repeatabilities of 0 and & 6%.…”
Section: Ammoniamentioning
confidence: 99%
“…Nitrite blank levels used to correct data were 0.0098 k 0.0009 pmol in front (three of six blanks analyzed) and 0.0061 f. 0.0006 pmol in back (two of six blanks analyzed) sorbent sections. Although spiked blanks were not tested, blanks spiked with 0.0064, 0.047, 0.11, and 0.74 pmol of NO; during related sample jobs yielded percentage recoveries of 153 f 14%, 103 * 4%, 106 rf 8 % , and 11 1 f 7%, respectively (Clauss et al 1994;Ligotke et al 1994). The analyses of'two samples were duplicated and yielded repeatabilities of & 0 and f 2 %.…”
Section: Nitrogen Oxidesmentioning
confidence: 99%
“…It is important to note that both sampling and analytical procedures were developmental as Tank C-104 was one of the first four trial sample jobs. Differences in sample preparation, sampling, and sample handling, compared with subsequent jobs, varied from those used after April 1994 (Ligotke et al 1994). Analytical accuracy was estimated based on procedures used.…”
Section: Inorganic Taskmentioning
confidence: 99%