2004
DOI: 10.1021/je0302248
|View full text |Cite
|
Sign up to set email alerts
|

Vapor−Liquid Equilibrium Measurements for Tetraethyl Orthosilicate + Ethanol at 24.00 kPa and 53.32 kPa

Abstract: The isobaric vapor-liquid equilibrium data of the tetraethyl orthosilicate and ethanol binary mixture were collected using a modified Othmer still at pressures of 24.00 kPa and 53.32 kPa. The experimental data showed that this mixture could be separated by a distillation process at lower temperatures under pressures of 24.00 kPa and 53.32 kPa than under atmospheric pressure. The experimental data were examined with the Herington thermodynamic consistency test and the χ 2 distribution of statistics. They are fa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…The saturated vapor pressures are calculated using Antoine's equation given as ln ( P i sat / mmHg ) = italicA italici italicB italici / false[ ( T / K ) + C i ] The Antoine constants ( A , B , C ) are obtained from literature , and are given in Table .…”
Section: Resultsmentioning
confidence: 99%
“…The saturated vapor pressures are calculated using Antoine's equation given as ln ( P i sat / mmHg ) = italicA italici italicB italici / false[ ( T / K ) + C i ] The Antoine constants ( A , B , C ) are obtained from literature , and are given in Table .…”
Section: Resultsmentioning
confidence: 99%
“…Vapor pressures were measured by the boiling point method. 3 The apparatus for vapor pressure measurement used here is similar to that of Huang et al 4 Temperatures were measured with thermocouples with an uncertainty of ( 0.05 K, and the still pressure was controlled at the desired value by a U-tube mercury manometer with an uncertainty of ( 0.03 kPa. The U-tube mercury manometer and thermometers were calibrated before experimental measurements.…”
Section: Methodsmentioning
confidence: 99%
“…Both vapor and liquid phases were kept at the same temperature for more than 1 h. VLE Measurement. The equipment and procedure for the measurement of low-pressure VLE are nearly the same as the one used by Huang et al 4 The equipment is a recirculation type, in which vapor is continuously recirculation. The thermocouples with an uncertainty of ( 0.1 K were used here, and the manometer was the same as the one used in the measurement of the vapor pressure of 2-chloromethylbenzoxazole.…”
Section: Methodsmentioning
confidence: 99%
“…The equipment and procedure for the measurement of low-pressure VLE are nearly the same as the ones described in the literature. 8,9 The apparatus mainly consists of a boiling chamber and a condenser. The total volume of the boiling chamber is about 400 cm 3 .…”
Section: ' Introductionmentioning
confidence: 99%