Abstract: Introduction: The quality of vesicourethral anastomosis (VUA) in laparoscopic radical prostatectomy (LRP) is associated with complications that could significantly affect quality of life.Aim: To compare different types of sutures (Chlosta's versus Van Velthoven versus V-Loc), used for VUA in LRP in terms of complication rates and continence recovery. Material and methods: Patients who underwent LRP between 2014 and 2018 in a tertiary center were enrolled in the study. Data were extracted from medical records. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(14 citation statements)
references
References 34 publications
0
14
0
Order By: Relevance
“…In the BNP and DULP group V-Loc™ was used in most cases, while in the group without BNP and DULP Van Velthoven sutures were was used in more than 30% of patients. The Van Velthoven suture was shown to be more time-consuming [16]. The other possible explanation for the longer anastomotic time in the group without BNP and DULP is the larger diameter of BN and more needle-passes needed for VUA.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…In the BNP and DULP group V-Loc™ was used in most cases, while in the group without BNP and DULP Van Velthoven sutures were was used in more than 30% of patients. The Van Velthoven suture was shown to be more time-consuming [16]. The other possible explanation for the longer anastomotic time in the group without BNP and DULP is the larger diameter of BN and more needle-passes needed for VUA.…”
Section: Discussionmentioning
confidence: 98%
“…The diameter of the distal urethra and bladder neck were mostly similar. The tension-free VUA was performed by using 3 different types of sutures [16]. After both ends of the suture were tied, the watertightness of the anastomosis was assessed by filling the bladder with 100-200 ml of sterile physiological saline.…”
Section: Surgical Techniquementioning
confidence: 99%
“…The number of stitches placed with 2D and 3D cameras was not different. It is difficult to achieve a water-tight anastomosis in human patients since a urinary catheter and an abdominal drain are maintained from several days to weeks to limit the risk of uroabdomen while waiting for the VUA to seal [10,[25][26][27][28][29][30][31]. Special clips are commonly used in human patients to maintain tension on the continuous line of suture and provide a better seal [11,24,32].…”
Section: Plos Onementioning
confidence: 99%
“…Waiter et al 3 reported less anastomotic leakage after radical prostatectomy in human patients with the unidirectional barbed suture. However, a urinary catheter is still maintained for 7 to 10 days after radical prostatectomy and VUA completed with unidirectional barbed sutures 3,6–13 …”
Section: Introductionmentioning
confidence: 98%
“…Since unidirectional barbed sutures do not require knot tying, it has been used during laparoscopic or robotic radical prostatectomy in human patients 3,6–13 . Waiter et al 3 reported less anastomotic leakage after radical prostatectomy in human patients with the unidirectional barbed suture.…”
Section: Introductionmentioning