2015
DOI: 10.1016/j.gaitpost.2015.03.326
|View full text |Cite
|
Sign up to set email alerts
|

Validity of GT3X and Actiheart to estimate sedentary time and breaks using ActivPAL as the reference in free-living conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
29
0
1

Year Published

2017
2017
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 55 publications
(32 citation statements)
references
References 31 publications
1
29
0
1
Order By: Relevance
“…The ActiGraph Inclinometer function on the hip accelerometer did not perform more favorably than the other ActiGraph methods. These findings are similar to those in adult samples that showed poor validity for using accelerometer cut points to assess sit-to-stand transitions (4, 16, 20, 23). …”
Section: Discussionsupporting
confidence: 85%
See 2 more Smart Citations
“…The ActiGraph Inclinometer function on the hip accelerometer did not perform more favorably than the other ActiGraph methods. These findings are similar to those in adult samples that showed poor validity for using accelerometer cut points to assess sit-to-stand transitions (4, 16, 20, 23). …”
Section: Discussionsupporting
confidence: 85%
“…Few studies have investigated accelerometers for assessing sit-to-stand transitions (4, 12, 16, 20, 23), and limitations of these studies were that all were in adults. The current study extended the previous literature by examining both epoch-level and hour-level validity of these measures in youth with overweight and obesity, a population frequently targeted for intervention (3).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A limitation of our study is that the assessment of movement behavior by the Actiheart ® monitor, which combines information of heart rate and body movements, may overestimate LPA and underestimate ST because not only PA but also sympathetic activation at rest increases heart rate. [47][48][49] In case of some children, it may also have been difficult to determine the time of falling asleep or waking up which may entail some error into ST estimation. Moreover, Actiheart ® is a device for measuring the intensity and energy expenditure of PA but not different types of PA that reflect PA as a behavior.…”
Section: Discussionmentioning
confidence: 99%
“…activPAL ™ is considered the reference method for estimating sedentary time in free-living individuals [54]. The inclinometer function is used to detect posture and thus can distinguish between sitting and standing.…”
Section: Methodsmentioning
confidence: 99%