Validity of correction factors applied to auditory steady-state responses (ASSRs) in normal hearing adults in chartr EP system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
7
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 27 publications
1
7
0
1
Order By: Relevance
“…In commercial acquisition systems, to counteract differences between ASSR and PTA, correction factors are applied based on the carrier frequency. Correction factors are set based on the difference between PTA and ASSR thresholds in subjects with varied hearing and age range ( 50 ). These correction factors can differ from one system manufacturer to another and are set as standard for most groups (i.e., adults, children, those with and without HL), which can result in variations in the threshold measures from one commercial system to another for the same subject ( 50 ).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In commercial acquisition systems, to counteract differences between ASSR and PTA, correction factors are applied based on the carrier frequency. Correction factors are set based on the difference between PTA and ASSR thresholds in subjects with varied hearing and age range ( 50 ). These correction factors can differ from one system manufacturer to another and are set as standard for most groups (i.e., adults, children, those with and without HL), which can result in variations in the threshold measures from one commercial system to another for the same subject ( 50 ).…”
Section: Discussionmentioning
confidence: 99%
“…Correction factors are set based on the difference between PTA and ASSR thresholds in subjects with varied hearing and age range ( 50 ). These correction factors can differ from one system manufacturer to another and are set as standard for most groups (i.e., adults, children, those with and without HL), which can result in variations in the threshold measures from one commercial system to another for the same subject ( 50 ). It may be that the correction factors applied to other age ranges may be suboptimal for older adults as used in the present study.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Outros estudos mostram que para detectar audição normal, a técnica dicótica múltipla da RAEE, realizadas neste estudo, ou seja, estimulação das duas orelhas e das quatro frequências simultaneamente é um método viável para estimar limiares auditivos que reduziriam substancialmente o tempo de registro em comparação com as técnicas convencionais de estímulo único (Herdman & Stapells, 2001;Ghasemahmad & Farahani, 2019).…”
Section: Discussionunclassified
“…ASSRs were performed at four carrier frequencies of 500, 1000, 2000, and 4000 Hz and intensity range of 10-80 dB SPL. The detailed modulation rate choice for each combination of MF and CF are as previously reported here [22].…”
Section: Methodsmentioning
confidence: 99%