2015
DOI: 10.1016/j.gie.2014.10.009
|View full text |Cite
|
Sign up to set email alerts
|

Validation of the diagnostic accuracy of probe-based confocal laser endomicroscopy for the characterization of indeterminate biliary strictures: results of a prospective multicenter international study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
58
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 104 publications
(61 citation statements)
references
References 19 publications
(18 reference statements)
2
58
0
Order By: Relevance
“…A significant difference has been observed regarding accuracy ( p = 0.0018). Another recent technique has been reported to further increase the sensitivity of cholangioscopy impression and tissue sampling, namely adding probe-based confocal laser endomicroscopy (pCLE) to the diagnostic workup [31, 35, 36]. However, the initial results were not replicated in a recent paper [37], and, therefore, the value of pCLE should be considered with caution, before it is recommended for routine practice.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A significant difference has been observed regarding accuracy ( p = 0.0018). Another recent technique has been reported to further increase the sensitivity of cholangioscopy impression and tissue sampling, namely adding probe-based confocal laser endomicroscopy (pCLE) to the diagnostic workup [31, 35, 36]. However, the initial results were not replicated in a recent paper [37], and, therefore, the value of pCLE should be considered with caution, before it is recommended for routine practice.…”
Section: Discussionmentioning
confidence: 99%
“…In a recent review of the literature from 2002 until 2012, including 16 studies and 1,556 patients, biliary brushing cytology was found to be associated with an overall sensitivity of 41.6% and a negative predictive value (NPV) of 58% [23]. To further increase the accuracy of brush cytology, many reports have described different techniques to improve positive yields, including stricture dilatation, repeat brushing, grasp and basket cytology, modified cytology brushes, the cell block method, digital image analysis, and fluorescence in situ hybridization (FISH) [24-31]. These methods all have different success rates, but most of them have increased costs.…”
Section: Introductionmentioning
confidence: 99%
“…8 Efforts to improve the diagnostic sensitivity have included the use of ERCP with fine-needle aspiration (FNA), probe-based confocal laser endomicroscopy (CLE), EUS with FNA, intraductal ultrasound, optical coherence tomography (OCT), and new tissue sampling accessories (including updated biopsy forceps and an endoscopic tissue scraper). [9][10][11][12] Studies have also evaluated fluorescence in situ hybridization (FISH) using probes for genetic alterations associated with CCA, with reported sensitivities ranging from 38% to 58% and specificities between 91% and 100%. 13,14 Newer FISH probes may increase the sensitivity to 65% and next generation genetic sequencing techniques are also promising, but the data is still limited.…”
Section: Sampling Of Biliary Pathologymentioning
confidence: 99%
“…Therefore, pCLE may decrease the number of ERCP needed for diagnosis. 103 Another pCLE study that used the older Miami classification showed accuracy of 81%, sensitivity 98%, and specificity 67% compared to accuracy 75%, sensitivity 45%, and specificity 100% of histopathology. 104 The Paris classification was recently validated for the characterization of indeterminate biliary strictures with increase in specificity, no impact in accuracy and fair interobserver variation (Table 3).…”
mentioning
confidence: 99%
“…104 The Paris classification was recently validated for the characterization of indeterminate biliary strictures with increase in specificity, no impact in accuracy and fair interobserver variation (Table 3). [103][104][105][106][107] pCLE was also studied in 15 PSC patients with dominant strictures, some of whom had biliary stents in place, and demonstrated a sufficient stricture visualization of 95%, sensitivity 100%, and specificity 61% in detecting neoplasia. 108 …”
mentioning