Validation of the Application of a Polar Organic Chemical Integrative Sampler (POCIS) in Non-steady-state Conditions in Aquatic Environments

Abstract: This study validated the chemicals monitoring ability of a polar organic chemical integrative sampler (POCIS) under non-steady-state conditions resulting from natural disasters and environmental accidents in aquatic environments via laboratory experiments. The goal of this work was to contribute toward monitoring the actual state of chemical contamination resulting from emergencies and natural disasters. A chamber replicating the chemical contamination of an aquatic environment established by a chemical exposu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
72
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 16 publications
(74 citation statements)
references
References 31 publications
1
72
1
Order By: Relevance
“…The experiments were carried out in glass beakers (φ105 × 150 mm), where each beaker contained 1 L of the sample solution that was stirred by cruciform stirring bars (φ40 × 14 mm) at 400 and 1500 rpm (HS-6DN; AS ONE) in an incubator (MIR-554-PJ; Panasonic) at 20°C in the dark. The flow velocities at 400 and 1500 rpm were reported as 1.0 and 18.0 cm/s, respectively, as measured by the alabaster mass loss (Noro et al 2019). The neonicotinoid mixture solution (20 mg/L each) was diluted 1000 times with ultrapure water to prepare a concentrated sample solution.…”
Section: Determination Of Linear Range and Sampling Rate By Static Rementioning
confidence: 99%
See 4 more Smart Citations
“…The experiments were carried out in glass beakers (φ105 × 150 mm), where each beaker contained 1 L of the sample solution that was stirred by cruciform stirring bars (φ40 × 14 mm) at 400 and 1500 rpm (HS-6DN; AS ONE) in an incubator (MIR-554-PJ; Panasonic) at 20°C in the dark. The flow velocities at 400 and 1500 rpm were reported as 1.0 and 18.0 cm/s, respectively, as measured by the alabaster mass loss (Noro et al 2019). The neonicotinoid mixture solution (20 mg/L each) was diluted 1000 times with ultrapure water to prepare a concentrated sample solution.…”
Section: Determination Of Linear Range and Sampling Rate By Static Rementioning
confidence: 99%
“…In recent years, various passive samplers have been devised for monitoring neonicotinoid pesticides in aquatic environments; these include Chemcatcher (Schäfer et al 2008; Sánchez-Bayo and Hyne 2014), a silicone rubber rod (Martin et al 2018), and the polar organic chemical integrative sampler (POCIS;Ahrens et al 2015;Challis et al 2018;Sultana et al 2018;Noro et al 2019;Xiong et al 2019). The collected amounts for Chemcatcher increased linearly for 20 d (Sánchez-Bayo and Hyne 2014).…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations