Validation of perinatal data in the Discharge Abstract Database of the Canadian Institute for Health Information

Abstract: We compared perinatal information submitted to the Canadian Institute for Health Information (CIHI) hospitalization database with information submitted to the Nova Scotia Atlee Perinatal Database (NSAPD) in order to assess the accuracy of the CIHI data. Procedures such as Caesarean delivery were coded accurately (i.e. sensitivity of 99.8%; specificity of 98.7%). Postpartum hemorrhage, induction of labour and severe intraventricular hemorrhage also had sensitivity and specificity rates above 85% and 95%, respec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
79
0
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 190 publications
(80 citation statements)
references
References 13 publications
0
79
0
1
Order By: Relevance
“…Some transcription errors are also possible with regard to the diagnoses of severe neonatal morbidity. On the other hand, previous studies [ 7 ] have shown that the database information is valid, and all diagnoses and procedures were coded using the same system (ICD-10CA and CCI) during the study period. Other study limitations include an evaluation restricted to birth weight-for-gestational age, whereas the INTERGROWTH standard (but not the Canadian reference) included other anthropometric measurements.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Some transcription errors are also possible with regard to the diagnoses of severe neonatal morbidity. On the other hand, previous studies [ 7 ] have shown that the database information is valid, and all diagnoses and procedures were coded using the same system (ICD-10CA and CCI) during the study period. Other study limitations include an evaluation restricted to birth weight-for-gestational age, whereas the INTERGROWTH standard (but not the Canadian reference) included other anthropometric measurements.…”
Section: Discussionmentioning
confidence: 99%
“…During the study period all diagnoses were coded using the International Classification of Diseases 10th revision, Canadian modification (ICD-10 CA), while procedures were coded using the Canadian Classification of Health Interventions (CCI). Information in the database is routinely checked for accuracy, and validation studies have shown the information to be complete and accurate [ 7 ].…”
Section: Methodsmentioning
confidence: 99%
“…A validation study using 2002 data (with information from a clinically focused database in the Canadian province of Nova Scotia as the gold standard) showed high rates of accuracy for the information on PPH in the Discharge Abstract Database [ 9 ]. The sensitivity and specificity rates for PPH were 90.2% and 98.2%, respectively, while the same rates for blood transfusion were 85.7% and 99.8%, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Diagnostic codes for these outcomes have good sensitivity and specificity relative to clinical data. 29,30…”
Section: Methodsmentioning