Validation of mRNA Quantification in Human Kidney by a Novel Fluorescent Nested RT-PCR Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

1996
1996
1996
1996

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Their sequences are identical to human ClC-2 at nt 2177-2195 and 2347-2369 respectively in the coding sequence (10). For evaluation of the ratio of the two forms, HRC5′ was labeled with blue fluorescent dye FAM (Applied Biosystems, Inc., Foster City, CA) (16), and 25-31 cycles or 29-37 cycles of amplification were performed depending on the yield of the PCR products. In each cycle, the reactions were denatured at 94_C for 1 min, annealed at 57_C for 40 s and extended at 72_C for 40 s. PCR products were separated on a Model 373 ABI DNA Sequencer and quantified by GeneScan software (Applied Biosystems).…”
Section: Pcr Amplificationmentioning
confidence: 99%
See 1 more Smart Citation
“…Their sequences are identical to human ClC-2 at nt 2177-2195 and 2347-2369 respectively in the coding sequence (10). For evaluation of the ratio of the two forms, HRC5′ was labeled with blue fluorescent dye FAM (Applied Biosystems, Inc., Foster City, CA) (16), and 25-31 cycles or 29-37 cycles of amplification were performed depending on the yield of the PCR products. In each cycle, the reactions were denatured at 94_C for 1 min, annealed at 57_C for 40 s and extended at 72_C for 40 s. PCR products were separated on a Model 373 ABI DNA Sequencer and quantified by GeneScan software (Applied Biosystems).…”
Section: Pcr Amplificationmentioning
confidence: 99%
“…Initial agarose gel electrophoresis of the PCR products using HRC5′ and HRC3′ suggested that the brain had the highest ratio of long/short form transcript compared with other tissues, especially the lung and the L2 cells. To quantify the ratio of these long and short transcripts, RT-PCR was performed with a fluorescent-labeled oligonucleotide (16). As only one pair of primers was used in the PCR reactions and two fragments were amplified, each fragment acted as the internal standard for the other.…”
Section: Adult Rat Lung Has a Decreased Long/short Form Ratio Of Clc-mentioning