2021
DOI: 10.1088/1361-6463/ac3daa
|View full text |Cite
|
Sign up to set email alerts
|

Validation of evaporation-determined model of arc-cathode coupling in the peak current phase in pulsed GMA welding

Abstract: A first experimental validation of the EDACC (evaporation-determined arc-cathode coupling) model is performend by comparing the experimental and simulated current in the peak current phase of a pulsed GMAW (gas metal arc welding) process. For this, the EDACC model was extended to limit the cathode surface temperature to a realistic value of <2400K. The information on the plasma for the EDACC model was gathered from literature and extrapolated and extended according to qualitative reasoning. The information … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 23 publications
0
2
0
Order By: Relevance
“…Detecting the effective arc edge became the main purpose in order to obtain the diameter of arc root (D r ), arc length (L) and arc projection width (D p ), as shown in Figure 1c, which are the most vital characterization parameters of the arc shape. As for Figure 1c, Figure 1c(1) is the original map captured by a high-speed camera, the regions of interest (ROI) are selected to highlight the feature areas and reduce the computational cost, as shown in Figure 1c(2), in grey in Figure 1c(3), median filtered in Figure 1c(4), the greyscale value 240 is binarized in Figure 1c(5), the ROI is reset to delete the reflections from the copper torch in Figure 1c (6), and a record of the highest point coordinate of the arc column and a reset of the grey-scale map by turning the greyscale value to 0 above the highest point is shown in Figure 1c (7). Taking a greyscale value, 100, to binarize again, as shown in Figure 1c(8), the arc column edge is finally captured; hence, the pixel values of D r , L and D p were easy to count.…”
Section: Arc Shape Characters Extracting Algorithmmentioning
confidence: 99%
See 1 more Smart Citation
“…Detecting the effective arc edge became the main purpose in order to obtain the diameter of arc root (D r ), arc length (L) and arc projection width (D p ), as shown in Figure 1c, which are the most vital characterization parameters of the arc shape. As for Figure 1c, Figure 1c(1) is the original map captured by a high-speed camera, the regions of interest (ROI) are selected to highlight the feature areas and reduce the computational cost, as shown in Figure 1c(2), in grey in Figure 1c(3), median filtered in Figure 1c(4), the greyscale value 240 is binarized in Figure 1c(5), the ROI is reset to delete the reflections from the copper torch in Figure 1c (6), and a record of the highest point coordinate of the arc column and a reset of the grey-scale map by turning the greyscale value to 0 above the highest point is shown in Figure 1c (7). Taking a greyscale value, 100, to binarize again, as shown in Figure 1c(8), the arc column edge is finally captured; hence, the pixel values of D r , L and D p were easy to count.…”
Section: Arc Shape Characters Extracting Algorithmmentioning
confidence: 99%
“…Pulsed-ultrasonic-assisted GMAW was analysed by Chen et al [3][4][5]; the results showed that arc length was compressed, metal transfer frequency increased, and weld appearance and mechanical properties were improved with the growing pulsed frequency. Simon [6] compared the experimental and simulated current in the peak current phase of GMAW-P process with an evaporation-determined arc-cathode coupling model, which reconstructed the critical link between surface temperature, plasma temperature and total current transmitted. Sathishkumar et al [7,8] proposed that double-pulsed GMAW had an increased cooling rate, refined grain, better mechanical property, and element segregation was completely precluded.…”
Section: Introductionmentioning
confidence: 99%