2016
DOI: 10.1080/03067319.2016.1249480
|View full text |Cite
|
Sign up to set email alerts
|

Validation of ELISA methods for search and quantification of β-n-methylamino-l-alanine in water and fish tissue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 31 publications
0
5
0
Order By: Relevance
“…False positives were observed in 5 of the 16 MilliQ blank samples measured among the five kits. Given the mixed results of the BMAA ELISA kit in the literature, it cannot be concluded with certainty that BMAA was present in these samples [ 38 , 39 , 40 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…False positives were observed in 5 of the 16 MilliQ blank samples measured among the five kits. Given the mixed results of the BMAA ELISA kit in the literature, it cannot be concluded with certainty that BMAA was present in these samples [ 38 , 39 , 40 ].…”
Section: Resultsmentioning
confidence: 99%
“…Notwithstanding the uncertainty involved with and variable performance of the five ELISA kits in numerous studies [ 38 , 39 , 45 , 46 , 47 , 48 , 49 ], they were selected for such practical considerations as availability for the desired analytes and ease of use.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The samples were analysed using ELISA kits from Abraxis (Microcystins ADDA–ELISA Microtiter Plate for MCs and BMAA kit), after a slow freeze–thaw cycle followed by ultrasonic treatment (ELMA S 10, Elmasonic, Singen, Germany), according to the manufacturer’s protocols. Despite initial criticisms of its reliability [ 65 ], the Abraxis BMAA kit was positively validated in recent studies [ 66 ]. The absorbance was read using a Mini photometer (model 6+, Metertech Inc., Taipei, Taiwan).…”
Section: Methodsmentioning
confidence: 99%
“…The BMAA detection literature is supported by several non-chromatography methods (Clausi et al 2016 ; Faassen et al 2013 ; Kerrin et al 2017 ; Beri et al 2018 ). However, we note that the currently available commercial ELISA is considered a flawed test by the scientific community generating many false positives and is not a good research tool in its present form (Faassen et al 2013 ; Bláhová et al 2017 ).…”
Section: The Detection and Quantification Of Bmaamentioning
confidence: 99%