2001
DOI: 10.1080/089419301753435710
|View full text |Cite
|
Sign up to set email alerts
|

Validation of Conductance Catheter System for Quantification of Murine Pressure-Volume Loops

Abstract: The purpose of this study was to define the validation methods and outcomes of a conductance catheter system specifically for in vivo murine cardiac hemodynamic analysis. To express the relationship between conductance and blood volumes, we used an in vitro model to derive a volume-conductance line. The volume-conductance line was used to compute raw volume from the modified conductance signals. The parallel volume was calibrated with hypertonic (15%) saline injected from extrajugular vein. The ventricular vol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
45
0

Year Published

2005
2005
2014
2014

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 46 publications
(47 citation statements)
references
References 24 publications
(51 reference statements)
2
45
0
Order By: Relevance
“…For either the systemic or the pulmonary circulation, E a can be calculated as the peak ventricular pressure divided by the stroke volume (48,49). The value of E a for the pulmonary circulation found here is approximately fourfold lower than the value of E a for the systemic vasculature of mice published previously (13,41,53,62). Given that the peak ventricular pressure in the right ventricle is approximately fourfold less than that in the left ventricle for the same CO, this result is good validation of the values obtained here.…”
Section: Discussionsupporting
confidence: 71%
“…For either the systemic or the pulmonary circulation, E a can be calculated as the peak ventricular pressure divided by the stroke volume (48,49). The value of E a for the pulmonary circulation found here is approximately fourfold lower than the value of E a for the systemic vasculature of mice published previously (13,41,53,62). Given that the peak ventricular pressure in the right ventricle is approximately fourfold less than that in the left ventricle for the same CO, this result is good validation of the values obtained here.…”
Section: Discussionsupporting
confidence: 71%
“…This methodology has been extensively validated in various species, including mice, which are substantially smaller than 4-wk-old rats (17)(18)(19). However, the experience with the conductance catheter applied in young rats is limited.…”
Section: Discussionmentioning
confidence: 99%
“…To determine parallel conductance, we performed intravenous hypertonic saline injections (10% saline, 20 L) (18,20). Parallel conductance was calculated as the mean of three consecutive assessments.…”
mentioning
confidence: 99%
“…The mitral valve flow was measured with Doppler, using a four-chamber view to compute the E-to-A ratios. After echo analysis, pressure-volume loops were acquired with our previously described Millar conductance catheter system methods (42,43).…”
mentioning
confidence: 99%