Validation of capnodynamic determination of cardiac output by measuring effective pulmonary blood flow: a study in anaesthetised children and piglets

Abstract: Under controlled experimental conditions, CO is associated with excellent agreement and good trending ability when compared with the gold standard CO. In the paediatric clinical setting, CO performs well; by contrast, CO, an operator- and anatomy-dependent technology, appears less reliable than CO.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
47
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 19 publications
(48 citation statements)
references
References 29 publications
0
47
1
Order By: Relevance
“…Previous animal studies and our overall data show conflicting results in terms of higher PEEP (increased lung volume) and accuracy of the CO EPBF . Interestingly, in a recent clinical study (manuscript) where CO EPBF was compared to transpulmonary 114 (6) 124 (4) 115 (4) 133 (9) 118 (8) 117 7124 (12) 116 (10) 133 (13) MAP (mmHg) 74 (10) 73 (9) 57 (9) 83 (15) 78 (11) 75 (11) 83 (16) 60 (11) 90 (18) 89 (8) mPAP (mmHg) 312 (17) 310 (12) 310 (12) 310 (12) 310 (12) 309 (11) 310 (12) 310 (12) 310 (12) 310 (13) RR ( 19 219 215 215 215 215 ( thermodilution during open abdominal surgery, no over estimation was observed even at high PEEP levels (up to 20 cmH 2 O) [24]. The current experimental protocol using the improved capnodynamic method departs from our previous study [6] in three ways.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Previous animal studies and our overall data show conflicting results in terms of higher PEEP (increased lung volume) and accuracy of the CO EPBF . Interestingly, in a recent clinical study (manuscript) where CO EPBF was compared to transpulmonary 114 (6) 124 (4) 115 (4) 133 (9) 118 (8) 117 7124 (12) 116 (10) 133 (13) MAP (mmHg) 74 (10) 73 (9) 57 (9) 83 (15) 78 (11) 75 (11) 83 (16) 60 (11) 90 (18) 89 (8) mPAP (mmHg) 312 (17) 310 (12) 310 (12) 310 (12) 310 (12) 309 (11) 310 (12) 310 (12) 310 (12) 310 (13) RR ( 19 219 215 215 215 215 ( thermodilution during open abdominal surgery, no over estimation was observed even at high PEEP levels (up to 20 cmH 2 O) [24]. The current experimental protocol using the improved capnodynamic method departs from our previous study [6] in three ways.…”
Section: Discussionmentioning
confidence: 99%
“…As previously described, the capnodynamic method with inspiratory holds (CO EPBFinsp ) showed acceptable performance in animals with low shunt [4], however when the animals were subjected to lavage-induced lung injury both accuracy and precision were affected [6]. After refinement of the method with the obliged holds inserted in expiration (CO EPBFexp ) instead of inspiration the performance in a porcine model with healthy lungs improved with sustained good trending ability during hemodynamic and ventilatory challenges [5,[7][8][9]. In addition, CO EPBFexp has been shown to provide stable CO monitoring in healthy infants undergoing cleft-lip surgery [8].…”
Section: Introductionmentioning
confidence: 95%
“…We previously validated a continuous capnodynamic approach to determine cardiac output (CO) based upon effective pulmonary blood flow (CO EPBF ) during normal, high, and low CO states in animals 1e3 and in healthy infants. 4 Agreement of the CO EPBF with other established CO comparators has been encouraging and is associated with good trending capabilities. 1e5 However, how CO EPBF performs in a situation of selective pulmonary vasoconstriction or pulmonary hypertension, resulting in a selective right ventricle increase in afterload and consequent variations in pulmonary carbon dioxide (CO 2 ) content, is unknown.…”
Section: Editor's Key Pointsmentioning
confidence: 91%
“…The anaesthetic and surgical procedures have been described in detail in our previous work. 4 In summary, the pigs were sedated with atropine 0.04 mg kg À1 (Mylan AB, Stockholm, Sweden), tiletamine-zolazepam (Zoletil, Vibrac Laboratories, Carros, France) 6 mg kg À1 , and xylazine chloride (Rompun, Bayer AG, Leverkusen, Germany) 2.2 mg kg À1 administered i.m. Infusion of fentanyl (Fentanyl B. Braun, Melsungen, Germany) 5 mg kg À1 , ketamine 30 mg kg À1 h À1 , midazolam 0.1 mg kg À1 h À1 , and fentanyl 4 mg kg À1 h À1 was used for maintenance of anaesthesia and rocuronium 2 mg kg À1 h À1 for muscle relaxation.…”
Section: Animal Preparationmentioning
confidence: 99%