2019
DOI: 10.1186/s12917-019-2211-3
|View full text |Cite
|
Sign up to set email alerts
|

Validation of an equine serum amyloid A assay with an unusually broad working range

Abstract: BackgroundSerum amyloid A (SAA) is a major equine acute phase protein and of great value in detection and monitoring of inflammation. A new immunoturbidometric assay based on monoclonal antibodies (VET-SAA, Eiken Chemical Co., Japan) may be useful for SAA measurements in routine diagnostic laboratories. The aim of the study was to validate the VET-SAA immunoturbidometric assay and use it to measure serum SAA concentrations in a variety of clinical cases. Precision was assessed by intra- and interassay coeffici… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
19
0
14

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(36 citation statements)
references
References 26 publications
3
19
0
14
Order By: Relevance
“…Species‐specific validation of any APP test is mandatory to obtain reliable data 13 . Our validation results show that every immunoassay performed reliably in donkeys, with good repeatability and accuracy (linearity under dilution) in our ranges of measurements, in agreement with requirements for this type of analysis 24,26 …”
Section: Discussionsupporting
confidence: 67%
See 3 more Smart Citations
“…Species‐specific validation of any APP test is mandatory to obtain reliable data 13 . Our validation results show that every immunoassay performed reliably in donkeys, with good repeatability and accuracy (linearity under dilution) in our ranges of measurements, in agreement with requirements for this type of analysis 24,26 …”
Section: Discussionsupporting
confidence: 67%
“…13 Our validation results show that every immunoassay performed reliably in donkeys, with good repeatability and accuracy (linearity under dilution) in our ranges of measurements, in agreement with requirements for this type of analysis. 24,26 One limitation of our study is more prolonged sampling post-LPS. Including donkeys with naturally occurring disease could clarify mid-and long-term variations in the concentrations of the APPs studied in this species.…”
Section: Discussionmentioning
confidence: 96%
See 2 more Smart Citations
“…4 Serum AA also was elevated in this horse [1,436 µg/mL (0-8 mg/µL)]. 5 These clinicopathological findings confirmed the diagnosis of AAamyloidosis with a unique phenotype called bullous amyloidosis.…”
Section: Case Reportsupporting
confidence: 63%