Validation of an analytical method for the refractive index measurement of glass fragments. Application to a hit-and-run incident

Abstract: A method to determine the refractive index (RI) of glass samples was validated in this research article. This validation was performed by studying analytical features such as the working range, precision, robustness, and bias. Locke silicone oil type B, glass standards type B and a sodium D source (589.3 nm) were chosen for a working RI range from 1.50225 to 1.52381, according to the typical RI values of glass samples of forensic interest. Robustness, calculated as Relative Standard Deviation (RSD) of slopes o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 33 publications
0
2
0
Order By: Relevance
“…The standard test method (ASTM E1967‐19, 2019) utilizes automated oil immersion refractometry with phase contrast microscopy to measure the refractive index of micron‐size particles. Due to controlled manufacturing processes, the RI is relatively homogeneous across a single object, and measurements can be obtained with high precision and accuracy when proper sampling protocols are followed (Alamilla et al, 2013; ENFSI, 2016; Garvin & Koons, 2011; Hicks, 2013; Insana & Buzzini, 2017; Munger et al, 2014; Newton, 2011; Trimpe & Sammarco, 2017). Current sampling and statistical comparison recommendations for RI are based on experimental studies assessing the RI micro‐heterogeneity and other sources of measurement variations (ASTM E1967‐19, 2019; Garvin & Koons, 2011; Newton, 2011).…”
Section: The Current State Of Methodologies For Forensic Glass Examin...mentioning
confidence: 99%
“…The standard test method (ASTM E1967‐19, 2019) utilizes automated oil immersion refractometry with phase contrast microscopy to measure the refractive index of micron‐size particles. Due to controlled manufacturing processes, the RI is relatively homogeneous across a single object, and measurements can be obtained with high precision and accuracy when proper sampling protocols are followed (Alamilla et al, 2013; ENFSI, 2016; Garvin & Koons, 2011; Hicks, 2013; Insana & Buzzini, 2017; Munger et al, 2014; Newton, 2011; Trimpe & Sammarco, 2017). Current sampling and statistical comparison recommendations for RI are based on experimental studies assessing the RI micro‐heterogeneity and other sources of measurement variations (ASTM E1967‐19, 2019; Garvin & Koons, 2011; Newton, 2011).…”
Section: The Current State Of Methodologies For Forensic Glass Examin...mentioning
confidence: 99%
“…A study comparing the use of refractive index and LA-ICP-MS for the forensic analysis of glass particles may also be of interest to those working in the eld. 291 The classication and discrimination of automotive glass of relevance in New Zealand has been the subject of a recent study. 292 The elemental composition of 243 samples of automotive glass was assessed using direct sampling with LA-ICP-MS.…”
Section: Glassesmentioning
confidence: 99%