Validation of an algorithm for continuous monitoring of atrial fibrillation using a consumer smartwatch

Abstract: BACKGROUND Consumer devices with broad reach may be useful in screening for atrial fibrillation (AF) in appropriate populations. However, currently no consumer devices are capable of continuous monitoring for AF.OBJECTIVE The purpose of this study was to estimate the sensitivity and specificity of a smartwatch algorithm for continuous detection of AF from sinus rhythm in a free-living setting.METHODS We studied a commercially available smartwatch with photoplethysmography (W-PPG) and electrocardiogram (W-ECG) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
50
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 52 publications
(53 citation statements)
references
References 24 publications
(28 reference statements)
3
50
0
Order By: Relevance
“…Only 3 patients here received false AF alarms, as low-quality PPG samples were discarded. Our findings also confirmed some earlier results ( Avram et al, 2021 ), that AF can be diagnosed more likely during the night compared to day-time. In resting patients with continuous PPG monitoring, AF was identified with a sensitivity of 81.0%, specificity of 96.4%, and PPV of 86.6% ( Kashiwa et al, 2019 ).…”
Section: Discussionsupporting
confidence: 93%
See 2 more Smart Citations
“…Only 3 patients here received false AF alarms, as low-quality PPG samples were discarded. Our findings also confirmed some earlier results ( Avram et al, 2021 ), that AF can be diagnosed more likely during the night compared to day-time. In resting patients with continuous PPG monitoring, AF was identified with a sensitivity of 81.0%, specificity of 96.4%, and PPV of 86.6% ( Kashiwa et al, 2019 ).…”
Section: Discussionsupporting
confidence: 93%
“…Photoplethysmography has been previously proven to be able to detect AF ( Bashar et al, 2019 ; Dörr et al, 2019 ; Fan et al, 2019 ; Kashiwa et al, 2019 ; Sološenko et al, 2019 ; Väliaho et al, 2019 ; Avram et al, 2021 ; Väliaho et al, 2021 ), but the signal quality is affected by motion artifacts ( Bashar et al, 2019 ; Sološenko et al, 2019 ; Nabavi et al, 2020 ). Recently, in a continuous AF monitoring study a total of 32.2% of the PPG data was classified as indeterminate, and in line with us more often during the day-time compared to night-time ( Avram et al, 2021 ). In our study, during the daytime, as much as 69.5% of the data recorded from ambulatory patients were discarded.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In many cases, a mobile device, e.g. smartwatch, is used as a real-time physiological monitoring system to monitor health and disease status of the patients, such as Li et al 12 , Kruizinga et al 13 , Ding et al 14 , Rodrigues et al 15 , Gruwez et al 16 , Perino et al 17 , Avram et al 18 , and Nasarre et al 19 . Li et al 12 shows the validity of measurements by smartwatches for 6 Minutes Walking Tests and consistency between Walking distances measured by doctors and by smartwatches.…”
Section: Related Workmentioning
confidence: 99%
“…Ding et al 14 , and Perino et al 17 present the use of a smartwatch and application that demonstrate reasonable accuracy for Atrial fibrillation detection and high usability. Avram et al 18 describes the estimation of the sensitivity and specificity of atrial fibrillation in the user's sinus rhythm in the user's daily life using a smartwatch. Rodrigues et al 15 shows the usability of detecting the position of Alzheimer's patients lost away.…”
Section: Related Workmentioning
confidence: 99%