Abstract: Background The Opti_Knee system, a marker-based motion capture system, tracks and analyzes the 6 degrees of freedom (6DOF) motion of the knee joint. However, the validation of the accuracy of this gait system had not been previously reported. The objective of this study was to validate and the system. Two healthy subjects were recruited for the study. Methods The 6DOF kinematics of the knee during flexion–extension and level walking cycles of the k… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 30 publications
(34 reference statements)
1
8
0
Order By: Relevance
“…All braces were placed on the right knee by the same professional orthopedist. We collected 3D kinematic data using a standard validated test procedure [ 14 ] under four conditions: walking without the OUB; walking with the OUB; jogging without the OUB; and jogging with the OUB. Data were collected while the subjects were walking at a speed of 3 km/h and jogging at a speed of 5 km/h on a treadmill [ 18 , 19 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…All braces were placed on the right knee by the same professional orthopedist. We collected 3D kinematic data using a standard validated test procedure [ 14 ] under four conditions: walking without the OUB; walking with the OUB; jogging without the OUB; and jogging with the OUB. Data were collected while the subjects were walking at a speed of 3 km/h and jogging at a speed of 5 km/h on a treadmill [ 18 , 19 ].…”
Section: Methodsmentioning
confidence: 99%
“…All kinematic data were acquired with an Opti_Knee system (Innomotion, Shanghai, China, Fig. 2 ), which is a 3D portable optical motion capture system and has repeatability in translation and rotation of 1.3 mm and 0.9°, respectively [ 13 , 14 , 16 ]. Two high-speed infra-red cameras (Polaris Spectra, Northern Digital Inc., Waterloo, ON, Canada) were integrated into a housing compartment to fix their relative 3D spatial positions.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3] The knee kinematics in 2 groups were compared at 3, 6, 12, and 24 months after surgery using Opti_Knee, a knee joint 3-dimensional motion analysis system (on Haiyidong Medical Technology Co., Ltd), recording the maximum step length, minimum step length, period of the limb walking, knee joint 6 degrees of freedom (flexion and extension angle, varus angle, internal and external rotation angle, front and back displacement, up and down displacement and internal and external displacement), and range of motion (maximum the difference from the minimum value). [20][21][22][23][24][25] The second look examination under arthroscopy was performed 12 months after surgery.…”
Section: Outcome Measuresmentioning
confidence: 99%
“…In this study, CKT technique was used during ACL reconstruction, and active rehabilitation plan was adopted after surgery. International Knee Documentation Committee (IKDC) and Lysholm function scores of patients were followed up 2 years after surgery, and Opti_Knee [20][21][22][23][24][25] (Innomotion, Shanghai, China) was used for kinematic analysis. This study assumed that the CKT group could obtain better functional scores and kinematic analysis results.…”