Validation of a novel sleep-monitoring system for diagnosing obstructive sleep apnea: A comparison with polysomnography

Abstract: Overnight polysomnography (PSG) is currently the gold standard for diagnosing obstructive sleep apnea (OSA); however, it is time-consuming, expensive and uncomfortable for the patient. A micromovement sensitive mattress (MSM) sleep-monitoring system was developed as an alternative to PSG, however, there has yet to be a study verifying the accuracy of diagnosing OSA with this device. Therefore, the present study assessed the validity of the MSM sleep-monitoring system. Chinese Han participants who were suspecte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…Table 7 shows, in the patient selection domain, 3 studies with a high risk of bias [ 29 , 47 , 50 ], 6 with a low risk [ 16 , 30 , 45 , 48 , 49 , 51 ], and 2 with unclear risk [ 46 , 52 ]. In turn, in the index test domain, 4 studies had a high risk [ 29 , 47 , 51 , 52 ], namely in questions Q5 and Q10, and the other 7 studies presented a low risk of bias [ 16 , 30 , 45 , 46 , 48 - 50 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Table 7 shows, in the patient selection domain, 3 studies with a high risk of bias [ 29 , 47 , 50 ], 6 with a low risk [ 16 , 30 , 45 , 48 , 49 , 51 ], and 2 with unclear risk [ 46 , 52 ]. In turn, in the index test domain, 4 studies had a high risk [ 29 , 47 , 51 , 52 ], namely in questions Q5 and Q10, and the other 7 studies presented a low risk of bias [ 16 , 30 , 45 , 46 , 48 - 50 ].…”
Section: Resultsmentioning
confidence: 99%
“…Another reason was that several designs were faltered in Q3: “Did the study avoid inappropriate exclusions? ” This is mostly because of an imprecise description of the reasons that led to those exclusions, as in one study where patients with back pain were excluded because this would make the use of the mattress sensor more difficult, which can overestimate the applicability of this type of tool [ 47 ]. Moreover, several studies did not include the results for all selected patients (P10), stating that it was attributable to a lack of space [ 29 ] or unreturned devices [ 54 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Home sleep apnea testing (HSAT) [1], as a means of screening sleep apnea, plays a crucial role in efficiently utilizing the limited medical resources of polysomnographic examination. Various types of sensors are utilized in HSAT devices, including those for measuring nasal pressure/temperature [2], respiratory inductance plethysmography [3], peripheral arterial tonometry [4,5], oximetry [6], electrocardiography [7,8], pulse wave photo-plethysmography [9], radio-wave Doppler effect [10] and bed-embedded micromotion sensors [11][12][13][14]. Generally, it is believed that the accuracy of sleep apnea detection improves with an increased number of signals measured [15].…”
Section: Introductionmentioning
confidence: 99%
“…Polysomnography (PSG) is the gold standard for the diagnosis of sleep disorders. However, many limiting factors, such as high cost, tedious operation with many lead wires, poor compliance, and lack of instrument resources [8,9], render PSG unable to be widely performed in clinical practice, resulting in a high missed diagnosis rate of OSA and other sleep-related diseases. Therefore, it is necessary to use a simpler and portable instrument to record sleep status.…”
Section: Introductionmentioning
confidence: 99%