Validation of a HPLC-DAD method for quantification of ascorbic acid in mixed juice powder of acerola and seriguela / Validação de um método HPLC-DAD para quantificação de ácido ascórbico de suco misto em pó de acerola e seriguela

Abstract: The objective of this work was to optimize extraction process and to validate the HPLC-DAD method for quantification of ascorbic acid content in mixed juice powder of acerola and seriguela with different dextrose equivalent maltodextrin (5, 10, 15) as an encapsulating agent. The influence of the extraction variables was studied through factorial design. Control variables were mass, percent of orthophosphoric acid and stirring time. Chromatographic method was validated in terms of precision, selectivity, linear… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…A viscometer (IKA ® ROTAVISC LO-VI S000, Staufen, Germany) was used to measure the viscosity of the LAA/HP- β -CD solution, at 23 ± 1 °C. The entrapment efficiency of LAA/HP- β -CD-NF was assessed by high-performance liquid chromatography (HPLC), as per the method described by Reibero et al, with minor modifications [ 31 ]. The quantitative analysis of LAA was performed utilizing an HPLC system (Agilent 1260 Infinity II, Waldbronn, Germany) equipped with a quaternary pump (G7111A, 1260 Quat pump VL), an automatic vial sampler injector (G7129A, 1260 Vialsampler), a multicolumn thermostat (G7116A, 1260 MCT), and a DAD detector (G7115A, 1260 DADWR).…”
Section: Methodsmentioning
confidence: 99%
“…A viscometer (IKA ® ROTAVISC LO-VI S000, Staufen, Germany) was used to measure the viscosity of the LAA/HP- β -CD solution, at 23 ± 1 °C. The entrapment efficiency of LAA/HP- β -CD-NF was assessed by high-performance liquid chromatography (HPLC), as per the method described by Reibero et al, with minor modifications [ 31 ]. The quantitative analysis of LAA was performed utilizing an HPLC system (Agilent 1260 Infinity II, Waldbronn, Germany) equipped with a quaternary pump (G7111A, 1260 Quat pump VL), an automatic vial sampler injector (G7129A, 1260 Vialsampler), a multicolumn thermostat (G7116A, 1260 MCT), and a DAD detector (G7115A, 1260 DADWR).…”
Section: Methodsmentioning