2008
DOI: 10.1097/bpo.0b013e318168c776
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a Genu Valgum Model in a Rabbit Hind Limb

Abstract: Numerous techniques exist to correct pediatric angular deformity by asymmetrically inhibiting physeal growth. Despite decades of surgical experience, little is known about the determinants of success or failure of temporary hemiepiphysiodesis. We lack a basic understanding of tolerances and kinematics of the surgically restrained physis. Furthermore, little is known about the influence of implant design and placement on efficacy of deformity correction and rebound growth. We have undertaken a pilot research st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
5
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…One reason for the overall outcome of stapling and tension-band plating appearing equal could be that the biological effect of both techniques is quite similar, despite a theoretical advantage in favor of tension-band plating. Several experimental studies have compared the techniques in both rabbit and porcine models (Mast et al 2008, Goyeneche et al 2009, Burghardt et al 2011, Kanellopoulos et al 2011). Migration of staples was reported in several of these studies.…”
Section: Discussionmentioning
confidence: 99%
“…One reason for the overall outcome of stapling and tension-band plating appearing equal could be that the biological effect of both techniques is quite similar, despite a theoretical advantage in favor of tension-band plating. Several experimental studies have compared the techniques in both rabbit and porcine models (Mast et al 2008, Goyeneche et al 2009, Burghardt et al 2011, Kanellopoulos et al 2011). Migration of staples was reported in several of these studies.…”
Section: Discussionmentioning
confidence: 99%
“…According to various clinical and experimental studies investigating the effect of temporary epiphysiodesis on coronal plane deformities, changes that have been achieved may later return to baseline after implant removal, due to a rebound effect (Stevens 2007 , Mast et al. 2008 , Yilmaz et al. 2014 ).…”
Section: Discussionmentioning
confidence: 99%
“…Mast et al. ( 2008 ) created tibial valgus deformity in rabbits and they reported that the deformity began to develop 1 week after the implantation of the plate or staple. In our study, because the plates were oblique, they could have led to a coronal plane deformity once they became parallel to the long axis of the tibia.…”
Section: Discussionmentioning
confidence: 99%
“…Four experimental animal studies have been published on the use of tension band plating 10–13. In one animal study rabbit hind limbs were allocated to either stapling, tension band plating, sham surgery, or no surgery 11. Staple migration was observed after 2 weeks treatment.…”
Section: Discussionmentioning
confidence: 99%
“…Tension band plating seems to be safe and an approximately 30% faster correction rate was noted in a recent article 9. Several experimental studies investigated the radiological effect of stapling and tension band plating10–13 and data are conflicting. The histomorphometric effect of the tension band plating technique is to our knowledge yet to be investigated.…”
mentioning
confidence: 99%