2019
DOI: 10.5664/jcsm.7932
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a Consumer Sleep Wearable Device With Actigraphy and Polysomnography in Adolescents Across Sleep Opportunity Manipulations

Abstract: Study Objectives: To compare the quality and consistency in sleep measurement of a consumer wearable device and a research-grade actigraph with polysomnography (PSG) in adolescents. Methods: Fifty-eight healthy adolescents (aged 15-19 years; 30 males) underwent overnight PSG while wearing both a Fitbit Alta HR and a Philips Respironics Actiwatch 2 (AW2) for 5 nights, with either 5 hours or 6.5 hours time in bed (TIB) and for 4 nights with 9 hours TIB. AW2 data were evaluated using two different wake and immobi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
65
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 109 publications
(73 citation statements)
references
References 23 publications
3
65
0
Order By: Relevance
“…The IS parameter varies from 0 to 1 and quantifies how well synchronized these rhythms are to external zeitgebers, such as the lightdark cycle (with higher IS values indicating stronger synchronization and more stable rhythms), whereas the IV parameter provides an assessment of the degree of fragmentation of the rest-activity patterns (with a value of 0 indicating a perfect sign wave rhythm and a value of two indicating Gaussian noise) with higher values considered to be markers of sleep-wake disturbances. 35,36 The Actiwatch has been shown to have >90% sensitivity for detecting sleep in adolescents, 37 with previous validation studies reporting no significant differences in sleep parameters between the Actiwatch and polysomnography. 38,39 Note that the sleep duration reported here was the time that the software determined the child to be asleep, and not just in bed; therefore sleep duration is not the same as the duration between bedtime and wake time.…”
Section: Data Analysesmentioning
confidence: 68%
“…The IS parameter varies from 0 to 1 and quantifies how well synchronized these rhythms are to external zeitgebers, such as the lightdark cycle (with higher IS values indicating stronger synchronization and more stable rhythms), whereas the IV parameter provides an assessment of the degree of fragmentation of the rest-activity patterns (with a value of 0 indicating a perfect sign wave rhythm and a value of two indicating Gaussian noise) with higher values considered to be markers of sleep-wake disturbances. 35,36 The Actiwatch has been shown to have >90% sensitivity for detecting sleep in adolescents, 37 with previous validation studies reporting no significant differences in sleep parameters between the Actiwatch and polysomnography. 38,39 Note that the sleep duration reported here was the time that the software determined the child to be asleep, and not just in bed; therefore sleep duration is not the same as the duration between bedtime and wake time.…”
Section: Data Analysesmentioning
confidence: 68%
“…Over time, the validity of consumer‐grade wearable devices has improved, and some devices now include a heart rate sensor, which enables detection of some sleep stages. Some of the more recent devices also demonstrate similar agreement with gold‐standard polysomnography and research‐grade devices 152‐155 . However, one drawback of wrist‐worn devices is that they will likely need to be recharged during the assessment period.…”
Section: Digital Phenotyping: Mobile Technology To Collect Pghdmentioning
confidence: 79%
“…Physicians should know about the characteristics and limitations of different sleep questionnaires, and they should combine sleep questionnaires with other evaluation tools when diagnosing patients. Recently, various sleep questionnaires and sleep diaries have been developed into mobile app versions, and consumer wearable devices for easier use [38,39].…”
Section: Resultsmentioning
confidence: 99%