2015
DOI: 10.1080/19443994.2015.1043652
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a chromatographic method for amoxicillin determination in wastewaters after its degradation by advanced oxidation process

Abstract: A rapid analytical procedure based on high performance liquid chromatography for identification and quantification of amoxicillin in wastewaters after its degradation by advanced oxidation process (AOP) was developed and validated. The proposed methodology was validated concerning to linearity, precision, limit of quantification, and limit of detection according to the required INMETRO and ANVISA (regulatory agencies in Brazil) standards. The method was applied to the determination of amoxicillin in wastewater… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…The different matrices used to prepare the calibration curves were analyzed previously with the HPLC-DAD method, and no Amox and Dox levels were detected. High values of the correlation coefficients (R 2 = 0.9999) were also obtained for the determination of Amox in tablets [6,41] and water [42], and for Dox in tablets [33] and water [44] by HPLC.…”
Section: Linearity Limit Of Detection (Lod) and Limit Of Quantificati...mentioning
confidence: 78%
See 2 more Smart Citations
“…The different matrices used to prepare the calibration curves were analyzed previously with the HPLC-DAD method, and no Amox and Dox levels were detected. High values of the correlation coefficients (R 2 = 0.9999) were also obtained for the determination of Amox in tablets [6,41] and water [42], and for Dox in tablets [33] and water [44] by HPLC.…”
Section: Linearity Limit Of Detection (Lod) and Limit Of Quantificati...mentioning
confidence: 78%
“…Therefore, an interm length should have been chosen for an even response from bought compound run on a single wavelength, resulting in a method with lower chromatograp ters, and a higher limit of detection (LOD) and limit of quantification (L quently, two different wavelengths (230 and 350 nm) were selected to monit tention time at 1.70 min) and Dox (retention time at 5.23 min) (Figure 2). The proposed method for the simultaneous determination of Amox and maceutical formulations and wastewater samples was validated relating to th of the chromatographic parameters (tailing factor, resolution, peak symmetr plates), LOD, LOQ, working and linear ranges, precision, and recovery, acco The proposed method for the simultaneous determination of Amox and Dox in pharmaceutical formulations and wastewater samples was validated relating to the conformity of the chromatographic parameters (tailing factor, resolution, peak symmetry, theoretical plates), LOD, LOQ, working and linear ranges, precision, and recovery, according to current guidelines and previously published papers [41][42][43][44][45][46][47].…”
Section: Methods Validationmentioning
confidence: 99%
See 1 more Smart Citation