2011
DOI: 10.1007/s13246-011-0060-x
|View full text |Cite
|
Sign up to set email alerts
|

Validation and automation of the DYNJAWS component module of the BEAMnrc Monte Carlo code

Abstract: The purpose of this work is to validate and automate the use of DYNJAWS; a new component module (CM) in the BEAMnrc Monte Carlo (MC) user code. The DYNJAWS CM simulates dynamic wedges and can be used in three modes; dynamic, step-and-shoot and static. The step-and-shoot and dynamic modes require an additional input file defining the positions of the jaw that constitutes the dynamic wedge, at regular intervals during its motion. A method for automating the generation of the input file is presented which will al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…In this study, BEAMnrc-2010 (v4-2.3.1) code system was used to calculate the dose. 23 The CPU used for the simulation was Intel (R), i7 CPU 930 @ 2.80 G Hz (four cores). EGSnrc-based BEAMnrc code was used to generate the phase space files for the linac, and the EGSnrcbased DOSXYZnrc code was use to calculated the dose in the virtual phantom.…”
Section: Iib2 Monte-carlo Simulationsmentioning
confidence: 99%
“…In this study, BEAMnrc-2010 (v4-2.3.1) code system was used to calculate the dose. 23 The CPU used for the simulation was Intel (R), i7 CPU 930 @ 2.80 G Hz (four cores). EGSnrc-based BEAMnrc code was used to generate the phase space files for the linac, and the EGSnrcbased DOSXYZnrc code was use to calculated the dose in the virtual phantom.…”
Section: Iib2 Monte-carlo Simulationsmentioning
confidence: 99%
“…First, linac head modeling with BEAMnrc and, secondly, phantom dose calculations in DOSXYZnrc for various soft‐tissue– and water‐equivalent materials. The linac head of a Varian Clinac 2100 (Varian Medical Systems, Palo Alto, CA) was simulated according to the vendor's specification as reported earlier (17) . The incident electron beam was modeled as an elliptical Gaussian profile with 0.1 cm width (source 19 in BEAMnrc).…”
Section: Methodsmentioning
confidence: 99%
“…17,18 For simulating EDWs, the DYNJAWS component module in BEAMnrc was employed. Jaw sequencing files were generated as per methodology developed by Kakakhel et al 19 Incident electron beam was modelled as a Gaussian profile using source 19. Photon cut-off and electron cut-off values of 0•01 MV and 0•7 MeV were used, respectively.…”
Section: Simulationsmentioning
confidence: 99%