Validation a Portable Monitoring Device for Sleep Apnea Diagnosis in a Population Based Cohort Using Synchronized Home Polysomnography

Abstract: The WP_100 was reasonably accurate for unattended home diagnosis of OSA in a population sample not preselected for OSA symptoms. The current design, including simultaneous home PSG recordings in population-based cohorts, is proposed as a reasonable validation standard for assessment of simplified recording tools for OSA diagnosis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
112
0
2

Year Published

2008
2008
2020
2020

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 137 publications
(118 citation statements)
references
References 40 publications
4
112
0
2
Order By: Relevance
“…Watch-PAT identifi ed the drivers with RDI > 15 with 89.1% sensitivity and 76.9% specifi city. There are studies confi rming the validation of Watch-PAT device simultaneously with PSG, 5,[8][9][10][11][12] detection of the arousals, 6,13 and assessment of CPAP effi cacy. 14,15 This is the fi rst study evaluating the reliability of Watch-PAT in a particular group, in this case, highway bus drivers.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Watch-PAT identifi ed the drivers with RDI > 15 with 89.1% sensitivity and 76.9% specifi city. There are studies confi rming the validation of Watch-PAT device simultaneously with PSG, 5,[8][9][10][11][12] detection of the arousals, 6,13 and assessment of CPAP effi cacy. 14,15 This is the fi rst study evaluating the reliability of Watch-PAT in a particular group, in this case, highway bus drivers.…”
Section: Discussionmentioning
confidence: 99%
“…Most of the studies are with Watch-PAT 100 device. 5,6,[8][9][10][11][12][13][14][15]18,19 Recently, Watch-PAT 200 has been shown to provide quick diagnosis in OSA and to be valid in the diagnosis of OSA during pregnancy. 20,21 Our particular question was the reliability of this device in the diagnosis of obstructive sleep apnea in highway bus drivers.…”
Section: Discussionmentioning
confidence: 99%
“…5 It has been shown to accurately detect OSA (in laboratory and ambulatory settings), [5][6][7][8] autonomic arousals, 9 and sleep/wake status. 10 The validity of using PAT and actigraphy signals derived from the PAT recorder to detect REM 11 and light/deep 12 sleep has also been demonstrated in two small studies.…”
Section: S C I E N T I F I C I N V E S T I G a T I O N Smentioning
confidence: 99%
“…However, PTT is not a current transaction for screening at OSAS patients. On the other hand, although PAT has been subject to the reports as a screening test with its high compliance with PSG, a completely dedicated device and software are needed (7)(8)(9)(10) Table 1. Demographic and HRV parameters of case and control groups cardiovascular diseases such as hypertension, ischemic heart disease, and congestive heart failure has been demonstrated quite well.…”
Section: Discussionmentioning
confidence: 99%