2011
DOI: 10.1016/j.atmosenv.2011.01.044
|View full text |Cite
|
Sign up to set email alerts
|

Validating a nondestructive optical method for apportioning colored particulate matter into black carbon and additional components

Abstract: Exposure of black carbon (BC) is associated with a variety of adverse health outcomes. A number of optical methods for estimating BC on Teflon filters have been adopted but most assume all light absorption is due to BC while other sources of colored particulate matter exist. Recently, a four-wavelength-optical reflectance measurement for distinguishing second hand cigarette smoke (SHS) from soot-BC was developed (Brook et al., 2010; Lawless et al., 2004). However, the method has not been validated for soot-BC … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
59
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 52 publications
(60 citation statements)
references
References 33 publications
(45 reference statements)
1
59
0
Order By: Relevance
“…Of particular note the multi-wavelength optical measurement of BC is calibrated gravimetrically by collecting, weighing and then optically measuring PM 2.5 filters of kerosene soot and assuming that 100% of the mass is BC (Yan et al , 2011); literature values consistently show values of 95% ± 5% (Lam et al , 2012). This comparison testing was conducted from the window of a fifth floor apartment along the W168th street, NYC, which is situated at an intersection of a busy street with idling ambulances and a truck route with heavy traffic.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Of particular note the multi-wavelength optical measurement of BC is calibrated gravimetrically by collecting, weighing and then optically measuring PM 2.5 filters of kerosene soot and assuming that 100% of the mass is BC (Yan et al , 2011); literature values consistently show values of 95% ± 5% (Lam et al , 2012). This comparison testing was conducted from the window of a fifth floor apartment along the W168th street, NYC, which is situated at an intersection of a busy street with idling ambulances and a truck route with heavy traffic.…”
Section: Methodsmentioning
confidence: 99%
“…A multi-wavelength optical method has been established for measuring BC levels collected on PM 2.5 Teflon filters via optical equipment purchased from Ocean Optics (Dunedin, FL) including a balanced deuterium tungsten halogen light source (DH-2000-BAL), an integrating sphere (ISP-50-8-R) modified to have a reflective white bottom, a lab-made filter holder, and an Ocean Optics USB4000-VIS-NIR fiber-optic spectrometer (Yan et al , 2011). Whereas the microAeth and full size Aethalometer measures the change in light attenuation between every time stamp (e.g., each min), from which the BC air concentration is calculated for that period of time, the multi-wavelength optical reflectance method determines the total BC mass loading on filters (based on an empirical gravimetric calibration) that occurred over the entire deployment period, which was 24 hrs in this experiment.…”
Section: Methodsmentioning
confidence: 99%
“…This focus overlooked a comparably long, if less ramified, history of filter optics studies using PTFE membranes as the collection substrate (Szkarlat and Japar 1981;Bennett and Patty, 1982;Campbell et al 1989Campbell et al , 1995Clarke et al 1996;Huffman 1996;Chow et al 2000;Taha et al 2007). Optical transmittance measurements are sometimes added to PTFE measurement suites as a proxy determination for "black carbon" (Cahill et al 1984;Nejedly et al 2003;Cuccia et al 2010;Barraza-Villarreal et al 2011) and, with sufficient spectral resolution, environmental tobacco smoke (Lawless et al 2004;Yan et al 2011). Massabo et al (2013) recently developed a multi-wavelength and multiangle optical system to make off-line MAAP-like absorption measurements on PTFE as well as quartz fiber filters.…”
Section: Ptfe Filters and The Improve Networkmentioning
confidence: 99%
“…However, researchers have reported filter-based methods using multiwavelength light extinction to determine cigarette smoke and some dusts concentrations in the presence of black carbon in atmospheric samples. [28][29][30] In order to use these methods to correct for interferences of DPM in occupational settings, further research and optimization would be necessary. 29 Borak et al evaluated the Aethalometer for determining realtime DPM concentrations at three occupational settings including one underground mine.…”
Section: Introductionmentioning
confidence: 99%
“…[28][29][30] In order to use these methods to correct for interferences of DPM in occupational settings, further research and optimization would be necessary. 29 Borak et al evaluated the Aethalometer for determining realtime DPM concentrations at three occupational settings including one underground mine. 31 The Aethalometer is a filterbased method which measures real-time black carbon in the atmosphere via absorption.…”
Section: Introductionmentioning
confidence: 99%