2016
DOI: 10.1016/j.aca.2015.11.035
|View full text |Cite
|
Sign up to set email alerts
|

Valence properties of tellurium in different chemical systems and its determination in refractory environmental samples using hydride generation – Atomic fluorescence spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
25
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(26 citation statements)
references
References 26 publications
1
25
0
Order By: Relevance
“…On the other hand, in mixed acidic systems (HNO 3 , HF with HCl), HCl seemingly does no harm, even on protracted heating. No losses were observed following digestions with HNO 3 -HF-HClO 4 mixtures (Chen et al 2016), an observation made earlier by Nicolas (1976) and Nazarenko and Ermakov (1972). Similarly, in the older literature, evaporation to dryness with concentrated HNO 3 is often used for the preparation of standards or sample digestions (Watterson and Neuerburg 1975), apparently without loss.…”
Section: Digestion Of Solid Matricessupporting
confidence: 77%
See 1 more Smart Citation
“…On the other hand, in mixed acidic systems (HNO 3 , HF with HCl), HCl seemingly does no harm, even on protracted heating. No losses were observed following digestions with HNO 3 -HF-HClO 4 mixtures (Chen et al 2016), an observation made earlier by Nicolas (1976) and Nazarenko and Ermakov (1972). Similarly, in the older literature, evaporation to dryness with concentrated HNO 3 is often used for the preparation of standards or sample digestions (Watterson and Neuerburg 1975), apparently without loss.…”
Section: Digestion Of Solid Matricessupporting
confidence: 77%
“…working at sub-boiling temperatures) are issued in classical analytical texts (Cooper 1971). A recent study by Chen et al (2016) concludes that, on the one hand, losses become inevitable in 3.0 mol L À1 HCl, and that these losses increase with temperature. Similarly, sample treatments with HF lead to losses (Nicolas 1976), which might be due to the formation of gaseous TeF 6 .…”
Section: Digestion Of Solid Matricesmentioning
confidence: 99%
“…Moreover, where certified values by aqua regia and another techniques (4-acid digestion) are available, as is the case for OREAS 603, 600 and 522, the aqua regia values are higher in one case (OREAS 603) and lower in the other two, with the difference not always being significant. Several authors claim that HCl never leads to Te losses when combined with some other acid (Chen et al 2016 and references cited therein). Yet, our results show that there is considerable variation between samples, with the added difficulty that aqua regia digestions can give divergent results depending on the precise protocol chosen, particularly at low concentrations, a point well illustrated by the samples OREAS 522, 135 and 903.…”
Section: Extraction Efficiencies Of the Individual Digestion Proceduresmentioning
confidence: 99%
“…minerals, rocks) with tellurium content 0.0-100 mg g -1 , [24], coal, [25], in lead and lead alloys [26], in the environment (water, plants, biological materials) [27][28][29]. Such techniques as atomic emission spectrometry (AES) with inductively coupled (ICP) or microwave (MP) plasma, in conjunction with mass spectrometry, [30][31][32][33], atomic fluorescence spectrometry, [34][35][36], the optical emission spectrometry [37] are used for the tellurium and tellurium trace analysis in various objects. In most of these works, tellurium is converted to the hydride before the spectrometric measurements to increase the sensitivity of the method.…”
Section: Procedures For the Decomposition Of Tellurium-containing Orgmentioning
confidence: 99%