2015
DOI: 10.1364/ao.54.002080
|View full text |Cite
|
Sign up to set email alerts
|

Vacuum ultraviolet spectropolarimeter design for precise polarization measurements

Abstract: Precise polarization measurements in the vacuum ultraviolet (VUV) region provide a new means for inferring weak magnetic fields in the upper atmosphere of the Sun and stars. We propose a VUV spectropolarimeter design ideally suited for this purpose. This design is proposed and adopted for the NASA-JAXA chromospheric lyman-alpha spectropolarimeter (CLASP), which will record the linear polarization (Stokes Q and U) of the hydrogen Lyman-α line (121.567 nm) profile. The expected degree of polarization is on the o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
4
2
2

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 18 publications
0
8
0
Order By: Relevance
“…CLASP has two optically symmetric channels, which provide two simultaneous measurements of orthogonal polarization states with two cameras (Narukage et al 2015(Narukage et al , 2017. The two cameras recorded the modulated intensity every 0.3 s in synchronization with the waveplate rotation.…”
Section: Clasp Observationsmentioning
confidence: 99%
“…CLASP has two optically symmetric channels, which provide two simultaneous measurements of orthogonal polarization states with two cameras (Narukage et al 2015(Narukage et al , 2017. The two cameras recorded the modulated intensity every 0.3 s in synchronization with the waveplate rotation.…”
Section: Clasp Observationsmentioning
confidence: 99%
“…The 400"-length and 1.45"-width slit can be seen at the center of the slit-jaw image. The plate scales are 1.03" (slit-jaw spatial), 1.11" (spectro-polarimeter spatial) and 0.0048 nm (spectro-polarimeter spectral) on the 13 µm pixel CCD cameras (Narukage et al, 2015). From the optical alignment of the instrument, a ∼3" spatial resolution is expected on both the slit-jaw and the spectropolarimeter.…”
Section: In-flight Polarization Calibrationmentioning
confidence: 99%
“…A unique pre-flight polarization calibration experiment was conducted at Lyman-α under vacuum condition (Giono et al, 2016a), which determined the instrument's response matrices X (Elmore, 1990) for each of the two channels inside the spectro-polarimeter (design presented in Narukage et al, 2015). This response matrix is defined as S =XS, where S is the incoming polarization signal expressed with its Stokes vector as (I,Q,U ) and S the measured polarization signal: (I ,Q ,U ) .…”
Section: Introductionmentioning
confidence: 99%
“…2). PMU was attached to the telescope side on the baseplate between the telescope and spectropolarimeter (the detailed optical design is shown by Narukage et al 8 ). The waveplate holder mounted on PMU was blackened to reduce stray light.…”
Section: Ground Tests and Installationmentioning
confidence: 99%