Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference
DOI: 10.1109/icps.1996.533940
|View full text |Cite
|
Sign up to set email alerts
|

Vacuum arc research expands interpretation of test data from vacuum interrupters

Abstract: Abstmet-Using high-speed movies of vacuum arcs between spiral contacts in conjunction with floating arc shields, the arc voltage, current and contact travel have been correlated with arc behaviors. These arc behaviors can be described by arc appearance diagrams in gapcurrent space. These allow the waveforms from high-power tests on spiral-contact vacuum interrupters to be evaluated for information on the internal arcing behavior and arc-induced damage. We have found that arc voltage traces can be examined duri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
1

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 11 publications
0
4
1
Order By: Relevance
“…Unlike the behavior with a floating shield [3], [4], the middle section of the arc column did not totally leave the contact gap when it interacted with the shield. Rather its periphery briefly spread out radially as in Fig.…”
Section: Fixed Shield Anld Contact As the Anode (Ip >15 Ka)contrasting
confidence: 54%
See 3 more Smart Citations
“…Unlike the behavior with a floating shield [3], [4], the middle section of the arc column did not totally leave the contact gap when it interacted with the shield. Rather its periphery briefly spread out radially as in Fig.…”
Section: Fixed Shield Anld Contact As the Anode (Ip >15 Ka)contrasting
confidence: 54%
“…and V(9. These are compared here to results with a floating shield of the same diameter [4]. Special attention is given to describing the conditions which produced cathode spots on the shield, and how the vacuum arc modes interacted with the shield.…”
mentioning
confidence: 96%
See 2 more Smart Citations
“…Vacuum interrupters also have no 'blind spots' or 'critical currents', i.e., a current range somewhere between load current and full short circuit current where the interrupter has difficulty interrupting. Beyond their full short circuit rating the probability of failure to interrupt gradually increases (15). VIS have been observed, however, to interrupt currents 25% higher than their full short circuit rating.…”
Section: Short Circuitmentioning
confidence: 96%