1980
DOI: 10.1103/physrevlett.44.1326
|View full text |Cite
|
Sign up to set email alerts
|

Vacancy-Carbon Interaction in Iron

Abstract: Electron-irradiated high-purity a-iron doped with various amounts of interstitial carbon impurities has been studied by positron-lifetime measurements. It is shown that during vacancy migration at 220 K an asymmetric vacancy-carbon pair is formed, where the carbon atom is located off the center of the vacancy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
44
0

Year Published

1981
1981
2017
2017

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 106 publications
(50 citation statements)
references
References 17 publications
6
44
0
Order By: Relevance
“…In such conditions, a large number of point defects are generated. However, the coalescence of vacancy and void formation, for instance in Fe, takes place at low temperature [25]. When vacancy clusters are decorated by carbon or hydrogen atoms, they can be stable at a higher temperature, as it was observed by Moutanabbir et al [26] in silicon.…”
Section: Discussionmentioning
confidence: 77%
“…In such conditions, a large number of point defects are generated. However, the coalescence of vacancy and void formation, for instance in Fe, takes place at low temperature [25]. When vacancy clusters are decorated by carbon or hydrogen atoms, they can be stable at a higher temperature, as it was observed by Moutanabbir et al [26] in silicon.…”
Section: Discussionmentioning
confidence: 77%
“…4b, remaining attached to five of the adjacent iron atoms. Positron annihilation studies indicate that the carbon atom is about 0.365a α from the vacancy center, forming a dumbell configuration with the vacancy [26]. In irradiated samples precipitation causes the carbon-vacancy complexes to dissociate at approximately 250 • C [27].…”
Section: Vacancy Type Complexesmentioning
confidence: 99%
“…No additional impurities were seen within detectable limit of EPMA (∼ 0.01wt%). Owing to the importance of C content on the formation of vacancy-carbon complexes 18 and carbides, carbon content was measured using combustion method and was found to be 65 ± 10 ppm, which is well below the solubility limit of ∼ 450 ppm at room temperature. Samples of 8 × 12 × 0.3 mm dimensions were homogenized at 1423 K (inside γ loop) for 1 hr followed by air quenching.…”
Section: Methodsmentioning
confidence: 99%