2019
DOI: 10.1016/j.jsps.2018.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Utilizing mixer torque rheometer in the prediction of optimal wet massing parameters for pellet formulation by extrusion/spheronization

Abstract: In this study, we aimed to optimize theophylline pellet formulations using a two-factor three-level full-factorial design (32) by monitoring the concentration of two pellet excipients, polyvinyl pyrrolidone K30 (PVP) binder solution (X1) and the hydrophilic excipient mannitol (X2). Their impact on pellet characteristics (responses) were evaluated. Increasing PVP concentration in the binder solution resulted in an increase in the wet mass torque value. The effect of mannitol, however, was antagonistic. Moreover… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…Each wet massing measuring cycle involved 60 s for mixing and 20 s for data logging (gathering). During the wet massing procedures, the consistency of pellet wet mass (represented by the mean line torque; Nm) was computed [21]. Moreover, the binder ratio (mL of PVP binder solution required for 1 g of powder to attain wet mass peak torque) was determined.…”
Section: Assessment Of Pellet Wet Mass (Mixer Torque Rheometry (Mtr))mentioning
confidence: 99%
See 1 more Smart Citation
“…Each wet massing measuring cycle involved 60 s for mixing and 20 s for data logging (gathering). During the wet massing procedures, the consistency of pellet wet mass (represented by the mean line torque; Nm) was computed [21]. Moreover, the binder ratio (mL of PVP binder solution required for 1 g of powder to attain wet mass peak torque) was determined.…”
Section: Assessment Of Pellet Wet Mass (Mixer Torque Rheometry (Mtr))mentioning
confidence: 99%
“…A similar finding was obtained by Ibrahim et al [27], who revealed an inverse relationship between the peak torque values of pellet wet mass and indomethacin release rate from pellet formulations. Moreover, Ibrahim et al [21] indicated that at a low pellet wet mass, the peak torque was associated with small pellet size and, hence, a rapid drug release rate.…”
Section: Effect On In Vitro Releasementioning
confidence: 99%
“…Wet powder rheometry is used to determine the granulation point of pharmaceutical formulations [24,26]. This method uses a mixer torque rheometer (MTR), and the software can be programmed to perform an analysis of the components of a formulation to obtain the exact amount of binding liquid and subsequently determine whether the flow of the granules is adequate to assess whether it will be difficult to compress in a compression machine.…”
Section: Introductionmentioning
confidence: 99%
“…A tool that has been explored to determine the granulation point of pharmaceutical formulations is wet powder rheometry [18,20]. The equipment is the Mixer Torque Rheometer (MTR) which, by simple programming the method and weighing 15-22 grams of each sample, is capable of indicating the granulation point by the relation of torque (Nm) versus Binder Ratio (mg.mL).…”
Section: Introductionmentioning
confidence: 99%