Utilization of sinogram affirmed iterative reconstruction on 128 multi slice computed tomography scan to reduce radiation dose and improve image quality on thorax multi slice computed tomography scan: chest phantom study

Abstract: Background: Thorax MSCT examination is a diagnostic imaging that is capable of displaying both normal and pathological lung and respiratory organs. MSCT examination also has a better level of sensitivity and specificity compared to other modalities, but the radiation exposure given is very high, so the radiation dose given to patients is high. The reduction in radiation dose is very important because of the direct exposure to sensitive tissue. One method of reducing radiation dose is by reducing the tube volta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
0
0
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 13 publications
0
0
0
1
Order By: Relevance
“…And in the research of Halinda et al (2019), they also optimized the exposure factor by reducing the tube voltage (kVp). The decrease in tube voltage causes the X-ray photon energy to penetrate the organ to decrease so that the radiation dose given to the patient will also be reduced (Fatmayanti et al, 2019). The results of the three articles show that reducing the exposure factor and using an iterative reconstruction algorithm does not reduce the quality of the resulting image because the IR algorithm plays a role in maintaining image quality when using a low exposure factor to minimize the radiation dose received by the patient.…”
Section: Effect Of Tube Voltage Settings and Idose Levels On Ctdi And...mentioning
confidence: 99%
“…And in the research of Halinda et al (2019), they also optimized the exposure factor by reducing the tube voltage (kVp). The decrease in tube voltage causes the X-ray photon energy to penetrate the organ to decrease so that the radiation dose given to the patient will also be reduced (Fatmayanti et al, 2019). The results of the three articles show that reducing the exposure factor and using an iterative reconstruction algorithm does not reduce the quality of the resulting image because the IR algorithm plays a role in maintaining image quality when using a low exposure factor to minimize the radiation dose received by the patient.…”
Section: Effect Of Tube Voltage Settings and Idose Levels On Ctdi And...mentioning
confidence: 99%
“…CT Scan (Computed Tomography Scan) merupakan alat penunjang diagnostik yang menggunakan sinar-X melalui teknik tomografi dan komputerisasi modern untuk pemeriksaan organ tubuh manusia (Fatmayanti et al, 2019). Sejak diperkenalkan untuk pertama kali pada tahun 1972 (Lim et al, 2016), CT scan telah berkembang menjadi alat pencitraan diagnostik yang sangat penting untuk beberapa aplikasi medis.…”
Section: Pendahuluanunclassified