2017
DOI: 10.3390/jof3030043
|View full text |Cite
|
Sign up to set email alerts
|

Utilization of High Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry for Characterization of 8-O-methylbostrycoidin Production by Species of the Fungus Fusarium

Abstract: The pigment 8-O-methylbostrycoidin is a polyketide metabolite produced by multiple species of the fungus Fusarium that infects plant crops, including maize. A technique was developed for the analysis of 8-O-methylbostrycoidin by high performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The quantitative nature of the LC-MS/MS experiment was demonstrated over a range of concentrations in maize. Limits of detection for the method (10 ng/g from 8-O-methylbostrycoidin spike… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
1

Year Published

2018
2018
2020
2020

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 18 publications
0
2
1
Order By: Relevance
“…Our analysis did not show the production by A1021B of 8-O-methylbostrycoidin, a polyketide pigment which has been reported in association with FA [48]. Furthermore, no trichothecenes were detected in any cultivation condition.…”
Section: Metabolome Analysiscontrasting
confidence: 79%
“…Our analysis did not show the production by A1021B of 8-O-methylbostrycoidin, a polyketide pigment which has been reported in association with FA [48]. Furthermore, no trichothecenes were detected in any cultivation condition.…”
Section: Metabolome Analysiscontrasting
confidence: 79%
“…HPLC-MS analyses were conducted in positive electrospray ionization mode to detect mycotoxins. HPLC-MS comparisons of ion mass and elution time with purified standards were used to identify the metabolites (Busman et al, 2012;Busman, 2017). Limits of quantitation for aurofusarin, BEA, enniatin B (ENNB), enniatin B1 (ENNB1), enniatin A (ENNA), and enniatin A1 (ENNA1) were 1 ng/µl.…”
Section: Mycotoxin Analysismentioning
confidence: 99%
“…HPLC-MS analyses were conducted in positive electrospray ionization mode to detect mycotoxins. HPLC-MS comparisons of ion mass and elution time with purified standards were used to identify the metabolites (Busman et al ., 2012;Busman, 2017). Limits of quantitation for aurofusarin, beauvericin, enniatin B, enniatin B1, enniatin A and enniatin A1 were 1 ng/µl.…”
Section: Mycotoxin Analysismentioning
confidence: 98%