2020
DOI: 10.1177/0897190020934304
|View full text |Cite
|
Sign up to set email alerts
|

Utilization of a Dextrose-Only Purge Solution for an LVAD in Patients With Suspected HIT: A Case Series

Abstract: The Impella devices are percutaneous intravascular ventricular assist devices indicated for use in patients with cardiogenic shock that occurs following acute myocardial infarction (MI) or open heart surgery. These devices must be used with a purge solution that contains heparin per manufacturer recommendation, which will prevent blood from reaching the motor causing pump thrombosis and mechanical failure. We describe the utilization of a dextrose-only purge solution plus systemic argatroban in 2 patients with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 7 publications
(17 reference statements)
0
2
0
Order By: Relevance
“…For patients who cannot tolerate heparin, D5 only in the purge solution combined with systematic anticoagulation via direct thrombin inhibitors is often utilized. 8 For our patient, D5 only was initially used with systematic bivalirudin; however, due to pump thrombosis requiring tissue plasminogen activator, bivalirudin was mixed in dextrose for the purge solution without recurrence of pump thrombosis.…”
Section: Discussionmentioning
confidence: 99%
“…For patients who cannot tolerate heparin, D5 only in the purge solution combined with systematic anticoagulation via direct thrombin inhibitors is often utilized. 8 For our patient, D5 only was initially used with systematic bivalirudin; however, due to pump thrombosis requiring tissue plasminogen activator, bivalirudin was mixed in dextrose for the purge solution without recurrence of pump thrombosis.…”
Section: Discussionmentioning
confidence: 99%
“…Further, some patients may require even further reduced concentrations or omission of heparin due to increased bleeding or heparin-induced thrombocytopenia (HIT). [4][5][6] While standardization of heparin concentrations is an established best practice for safe medication use, 7 these complex patients may require alternative concentrations. Here, we discuss standardizing alternative low-dose heparin concentrations for purge solutions, which we have prebuilt in our system as standardized choices to reduce risk medication errors.…”
Section: To the Editormentioning
confidence: 99%