Utility of the Modified Isolated-check Visual Evoked Potential Technique in Functional Glaucoma Assessment

Abstract: Précis: Cortical response to low-contrast stimuli, as measured by isolated-check visual evoked potential (icVEP) technology, has the potential to provide functional assessment that may complement standard achromatic perimetry in assessing glaucomatous change. Purpose: To evaluate the utility of modified icVEP testing in detecting functional glaucomatous damage. Materials and Methods: Subjects who met predet… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 28 publications
1
6
0
Order By: Relevance
“…And the AUC of 16% DOM was 0.780. The accuracies of ic-VEP to differentiate patients with glaucoma from normal people differ according to the previous studies 14–16. The sensitivities differ by 70% from 82% and the specificities are between 75% and 99%.…”
Section: Discussionmentioning
confidence: 92%
See 2 more Smart Citations
“…And the AUC of 16% DOM was 0.780. The accuracies of ic-VEP to differentiate patients with glaucoma from normal people differ according to the previous studies 14–16. The sensitivities differ by 70% from 82% and the specificities are between 75% and 99%.…”
Section: Discussionmentioning
confidence: 92%
“…Previous studies used the settled parameters of the machine as a tool for early POAG detection but did not modulate M-biased or P-biased stimulation. [14][15][16] At present, early glaucomatous visual impairment is still controversial, [17][18][19][20][21][22][23] and further clinical trials about objective evidence of early dysfunction in glaucoma are needed.…”
Section: What This Study Addsmentioning
confidence: 99%
See 1 more Smart Citation
“… “ic-VEPs” (isolated-check VEPs, [ 49 ]) sweep contrast (or at least use 10% and 80%) and use the signal-to-noise ratio as a marker. With a commercial version (using an OLED monitor, so laudably without luminance artifacts), in a 140-eyes cross-sectional study, Kolomeyer et al [ 50 ] reported AUCs of up to 0.79, depending on whether favoring sensitivity or specificity. They also found progressive VEP affection from pre-perimetric over early and moderate to severe glaucoma.…”
Section: Vepmentioning
confidence: 99%
“…Recently, isolated-check VEPs (icVEPs), a new visual electrophysiology technology, have been reported to be able to detect glaucomatous visual damage early and quickly [ 7 ]. In recent years, this technique has been applied to detect optic nerve damage of glaucoma [ 8 , 9 , 10 , 11 , 12 , 13 ] and other diseases such as traumatic optic neuropathy [ 14 ] and dysthyroid optic neuropathy [ 15 , 16 ]. The specificity and sensitivity values in detecting glaucomatous optic nerve defects are 84.6–100% and 53.1–83%, respectively [ 7 , 8 , 9 , 10 , 11 ].…”
Section: Introductionmentioning
confidence: 99%