Utility of SPR technology in biotherapeutic development: Qualification for intended use

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…Kinetic analyses were conducted at low ligand levels (150 RU). In addition to that, the TNF-α sample solution was injected at 50 μL/min to reduce mass transport limitation on the chip surface [ 35 ]. TNF-α samples were prepared with a concentration range from 3.33 to 30 nM (3-fold dilution).…”
Section: Resultsmentioning
confidence: 99%
“…Kinetic analyses were conducted at low ligand levels (150 RU). In addition to that, the TNF-α sample solution was injected at 50 μL/min to reduce mass transport limitation on the chip surface [ 35 ]. TNF-α samples were prepared with a concentration range from 3.33 to 30 nM (3-fold dilution).…”
Section: Resultsmentioning
confidence: 99%
“…SPR is a well-established technique that has been utilized to investigate various biophysical interactions, especially those targeting proteins. However, using SPR for direct analysis of interactions between small molecules, such as small peptides, and proteins has commonly been a difficulty, largely due to the low signal change caused from small molecule interactions . We, therefore, utilized a competition assay to evaluate the binding of the peptide to the SARS-CoV-2-spike protein using SPR spectroscopy, with Figure providing a schematic of this competition assay.…”
Section: Resultsmentioning
confidence: 99%
“…Meanwhile, the horizontal configuration is more suitable to perform measurements in the presence of solutions, even allowing dynamic set-ups with microfluidic cells. The vertical optical device (Figure 1b) comprises a rectangular planar support (1), three planar mirrors (2), and a biconcave lens (3). The grating (4) must be positioned vertically in the special support at the center of the plane.…”
Section: The Proposed Systemmentioning
confidence: 99%
“…Surface plasmon resonance (SPR) is a valuable optical analytic tool used as a sensing technique in a wide range of applications including studies of biomolecular interactions [1,2], drug discovery [3,4], and pathogen detection [5,6]. In recent years, there has been an evergrowing interest in optical detection techniques such as absorbance [7][8][9] and SPR [10][11][12], since they guarantee high sensitivity, immunity to external disturbance, stability, and low noise [13].…”
Section: Introductionmentioning
confidence: 99%