2015
DOI: 10.1007/s11581-015-1602-0
|View full text |Cite
|
Sign up to set email alerts
|

Utility of gold nanoparticles/silica modified electrode for rapid selective determination of mebeverine in micellar medium: comparative discussion and application in human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
22
1
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(25 citation statements)
references
References 34 publications
1
22
1
1
Order By: Relevance
“…The literature survey reveals several analytical methods for MEB quantification, such as chromatographic [21,22], GC-MS [23], spectrophotometric [24,25], spectrofluorometric [25,26] and electrochemical methods [27][28][29][30][31][32][33]. Carbon paste electrodes (CPEs) have been applied successfully for MEB quantification either using potentiometric [31] or voltametric techniques [32,33]. This can be attributed to their low cost, low background currents, possibility to be used over a wide studied potential window, ease of surface renewability as well as modification simplicity and utilization variety when compared with other solid electrodes [34][35][36][37].…”
Section: Introductionmentioning
confidence: 99%
“…The literature survey reveals several analytical methods for MEB quantification, such as chromatographic [21,22], GC-MS [23], spectrophotometric [24,25], spectrofluorometric [25,26] and electrochemical methods [27][28][29][30][31][32][33]. Carbon paste electrodes (CPEs) have been applied successfully for MEB quantification either using potentiometric [31] or voltametric techniques [32,33]. This can be attributed to their low cost, low background currents, possibility to be used over a wide studied potential window, ease of surface renewability as well as modification simplicity and utilization variety when compared with other solid electrodes [34][35][36][37].…”
Section: Introductionmentioning
confidence: 99%
“…1) potent direct antispasmodic agent used mainly for the smooth muscles of the gastrointestinal tract and particularly effective against the colonic spasm [1] It is used in the treatment of abdominal pain and spasm associated with gastrointestinal disorders such as mucous colitis [2] Due to the vital importance of MV.HCl, there are many reported methods for its determination in its pharmaceutical formulations and in biological fluids. Among these methods are HPLC [3][4][5][6][7], spectrophotometry [8][9][10][11], GC-MS [12], and electrochemistry [13][14][15][16]. On one side, most of the reported chromatographic is expensive method of analysis required a high maintenance cost, high acquisition cost, time-consuming procedures, senetive equilibration, it also may requires derivatization treatment prior to analysis and expensive grades of reagents, eluents, and equipment [3][4][5][6][7]12], On other side, there are some reported electrochemical methods based on potentiometry [13], square-wave anodic stripping voltammetry (SW-ASV) [14,16] and differential pulse voltammetry (DPV) [15] listed in (Table 1).…”
Section: Introductionmentioning
confidence: 99%
“…Among these methods are HPLC [3][4][5][6][7], spectrophotometry [8][9][10][11], GC-MS [12], and electrochemistry [13][14][15][16]. On one side, most of the reported chromatographic is expensive method of analysis required a high maintenance cost, high acquisition cost, time-consuming procedures, senetive equilibration, it also may requires derivatization treatment prior to analysis and expensive grades of reagents, eluents, and equipment [3][4][5][6][7]12], On other side, there are some reported electrochemical methods based on potentiometry [13], square-wave anodic stripping voltammetry (SW-ASV) [14,16] and differential pulse voltammetry (DPV) [15] listed in (Table 1). It is noticed that Potentiometry and SW-AdASV onto bare Carbon paste electrode CPE did not offer a sufficient sensitive quantitation limit of MV.HCl that can cover pharmacokinetic studies and therapeutic drug monitoring.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Diferentes modificadores são utilizados para o preparo dos CMCPE empregados na determinação de fármacos em formulações farmacêuticas e fluídos biológicos. Dentre eles pode-se destacar: nanotubos de carbono de paredes múltiplas [46], nanopartículas de metais [47,48], zeólitas [49], óxido de grafeno [50], compostos inorgânicos [51], sílica funcionalizada [52], entre outros.…”
Section: Eletrodos De Pasta De Carbono Quimicamente Modificados -Cmcpeunclassified