2012 First National Conference for Engineering Sciences (FNCES 2012) 2012
DOI: 10.1109/nces.2012.6740457
|View full text |Cite
|
Sign up to set email alerts
|

Using seven-level cascade H-bridge inverter with HVDC system to improve power quality

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
4
1

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 7 publications
0
8
0
Order By: Relevance
“…The ASCC is designed and controlled depending on a modified PWM (MPWM) algorithm. This type of a new active ISSN: 2302-9285  power filter designs to eliminate resonance problems caused in the AC power system, minimize THD, and accurate power factor as the same time depending on the MPWM algorithm [25].…”
Section: Active Static Compensation Circuitmentioning
confidence: 99%
See 2 more Smart Citations
“…The ASCC is designed and controlled depending on a modified PWM (MPWM) algorithm. This type of a new active ISSN: 2302-9285  power filter designs to eliminate resonance problems caused in the AC power system, minimize THD, and accurate power factor as the same time depending on the MPWM algorithm [25].…”
Section: Active Static Compensation Circuitmentioning
confidence: 99%
“…In the MPWM algorithm, the reference compensated current (ic) is calculated as the difference between the load current signal (IL) and the desired reference AC current signal (id-ref). The id-ref is produced as the product of the both unity sinusoidal waveform of the main voltages (sin(wt)) and the fundamental component of the load current (IL1) [25].…”
Section: Active Static Compensation Circuitmentioning
confidence: 99%
See 1 more Smart Citation
“…Each inverter cell is set to produce three output voltage (+Vdc, 0, and −Vdc) [4]. Improving the MLI output voltage levels enhance system quality, reduce distortion, and make it is suitable for HV applications [5]. Multilevel inverter contains cascaded single-phase inverters with The challenging to get efficient DC-AC converter is to reduce number of power electronics switches.…”
Section: Introductionmentioning
confidence: 99%
“…Multilevel inverter can achieve the fundamental and high switching frequency based on PWM [4]. Increasing the multilevel inverter output voltage levels improve power quality of the output AC voltage and reduce THD [5], [6]. Different DC voltage values with lower power switch devices used past years to obtain high output voltage levels.…”
Section: Introductionmentioning
confidence: 99%