2007
DOI: 10.1016/j.jpba.2007.08.010
|View full text |Cite
|
Sign up to set email alerts
|

Using of HPLC coupled with coulometric detector for the determination of biotin in pharmaceuticals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 18 publications
0
5
0
Order By: Relevance
“…11,14,18 Unlike the gas chromatographic, HPLC, CE and electroanalytical procedures, the instrument is simple and is not of high cost. [11][12][13][14][15][16][17][18][19][20][21][22] In addition, the developed method is highly sensitive, accurate, precise and selective. These advantages encourage the application of the developed method in routine quality control analysis of the biotin.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…11,14,18 Unlike the gas chromatographic, HPLC, CE and electroanalytical procedures, the instrument is simple and is not of high cost. [11][12][13][14][15][16][17][18][19][20][21][22] In addition, the developed method is highly sensitive, accurate, precise and selective. These advantages encourage the application of the developed method in routine quality control analysis of the biotin.…”
Section: Resultsmentioning
confidence: 99%
“…As some studies suggest, the enzyme biotinidase, which is involved in the in vivo recycling of the vitamin, serves as a carrier protein for the transport of biotin into the cell as well as a biotin-binding protein in serum. 5 Several analytical methods have been developed for the determination in different sample matrices, e.g., UV-visible spectrophotometry, 6 spectrofluorimetry, 7 electrometry 8-10 high performance liquid hromatography (HPLC), [11][12][13][14][15][16] liquid chromatography-mass spectrometry (LC-MS), 17,18 capillary zone electrophoresis, 19,20 enzyme-linked immunosorbent assay (ELISA). 21 In this study, a highly sensitive spectrofluorimetric method was developed to assay biotin in pharmaceutical preparations.…”
Section: Introductionmentioning
confidence: 99%
“…As was mentioned above, the combination of high-performance liquid chromatography with coulometric detection (HPLC-CD) is one of the ways to improve the selectivity of AOs quantification in the samples of complex matrix. Coulometric detection is characterized by high sensitivity, low detection limits, lower background currents and less potential interferences, absolute quantification without calibration graph, possibility of trace analysis [80][81][82]. The application of several electrodes in series (up to sixteen coulometric detectors) allows to build a coulometric array working in a screening mode [83].…”
Section: Coulometric Detection Of Antioxidants In Chromatography and Flow Systemsmentioning
confidence: 99%
“…Likewise, the majority of the cited methods employed UV detection, either at a single wavelength or multiple wavelengths (i.e., photodiode array detector) to improve performance. However, a few used other types including coulometric (197,223), light scattering (200), and fluorescence (205) detection.…”
Section: Separation-based Methodologymentioning
confidence: 99%