Using FACTS devices to resolve congestions in transmission grids

Abstract: Increased electric power consumption causes transmission lines to be driven close to or even beyond their transfer capacities resulting in overloaded lines and congestions. Flexible AC Transmission Systems (FACTS) provide an opportunity to resolve congestions by controlling power flows and voltages. The focus in this paper lies on the Thyristor Controlled Series Compensator (TCSC) and the Static Var Compensator (SVC) as they are already in use.In general, SVCs and TCSCs are controlled locally without any coord… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0

Publication Types

Select...
3
3
1

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(24 citation statements)
references
References 12 publications
(14 reference statements)
0
24
0
Order By: Relevance
“…where the values of u B,SVC,min,m and u B,SVC,max,m are determined by the size of the device [7]. The constraints of an SVC at bus m are assigned to the node m.…”
Section: Facts Devices Svcmentioning
confidence: 99%
See 1 more Smart Citation
“…where the values of u B,SVC,min,m and u B,SVC,max,m are determined by the size of the device [7]. The constraints of an SVC at bus m are assigned to the node m.…”
Section: Facts Devices Svcmentioning
confidence: 99%
“…where the values of u X,TCSC,min,mn and u X,TCSC,max,mn are determined by the size of the TCSC and the characteristics of the line in which it is placed, since due to the physics the allowed compensation rate of the line u X,TCSC,mn /η X,mn is limited [7]. The constraints of the TCSC at the line between bus m and n are assigned to node m, if m < n, and to node n otherwise.…”
Section: Tcscmentioning
confidence: 99%
“…Shao and Vittal (2006a) proposes the use of FACTS devices as a corrective mechanism to relieve overloading and voltage violations. Glanzmann and Andersson (2005) proposes the use of FACTS devices as a congestion management tool. In this paper, the focus will be on transmission switching, i.e., the opening and closing of circuit breakers in order to temporarily take transmission assets (lines or transformers) in and out of service.…”
Section: Introductionmentioning
confidence: 99%
“…where the values of X TCSC,min and X TCSC,max are determined by the size of the TCSC device and the characteristics of the line in which it is placed, since due to the physics the allowed compensation rate of the line is limited [17]. This range is set to 40% inductive and 90% capacitive.…”
Section: A Steady-state Modelmentioning
confidence: 99%