1981
DOI: 10.1253/jcj.45.366
|View full text |Cite
|
Sign up to set email alerts
|

Usefulness of 24-hour Recordings of Electrocardiogram for the Diagnosis and Treatment of Arrhythmias with Special Reference to the Determination of Indication of Artificial Cardiac Pacing : Present Status and Future of Clinical Electrocardiology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

1983
1983
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…It is difficult to assign specific values to the severity of bradycardia or cardiac arrest in these cases; however, as proposed in the 2013 AHA/ACC Guidelines, 116 ventricular rate <40 beats/min and ventricular arrest >3 s are used as reference values 117,118 . The recommendations are shown in Table 7 111‐123 …”
Section: Cardiac Implantable Electronic Devices (Cieds)mentioning
confidence: 99%
See 2 more Smart Citations
“…It is difficult to assign specific values to the severity of bradycardia or cardiac arrest in these cases; however, as proposed in the 2013 AHA/ACC Guidelines, 116 ventricular rate <40 beats/min and ventricular arrest >3 s are used as reference values 117,118 . The recommendations are shown in Table 7 111‐123 …”
Section: Cardiac Implantable Electronic Devices (Cieds)mentioning
confidence: 99%
“…Although pacemaker implantation is not indicated for asymptomatic sinus bradycardia, syncope may result in injuries such as fractures. It is important to ascertain the symptoms that occur because of bradycardia, sinoatrial block, sinus arrest, or impaired heart rate response during exercise due to a decline in the primary function of the sinus node (syncope, convulsions, blacking out, dizziness, shortness of breath, fatigue, heart failure, etc) 119,120,129‐135 . Primary sinus node dysfunction is associated with essential reduction in sinus node function.…”
Section: Cardiac Implantable Electronic Devices (Cieds)mentioning
confidence: 99%
See 1 more Smart Citation
“…117,118 The recommendations are shown in Table 7. [111][112][113][114][115][116][117][118][119][120][121][122][123]…”
Section: ▋ 31 Atrioventricular Blockmentioning
confidence: 99%
“…Holter electrocardiogram can be used for diagnosis about the pacemaker adaptation and for detection of transient arrhythmia [1, 2]. The SpO 2 measurement monitors the oxygen saturation in the blood percutaneously by a pulse oximeter equipped to a fingertip.…”
Section: Introductionmentioning
confidence: 99%