2011
DOI: 10.1016/j.aca.2011.02.028
|View full text |Cite
|
Sign up to set email alerts
|

Used gold nano-particles as an on/off switch for response of a potentiometric sensor to Al(III) or Cu(II) metal ions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 43 publications
(12 citation statements)
references
References 42 publications
(44 reference statements)
0
11
0
1
Order By: Relevance
“…In our previous works, we used some nanoparticles in electrochemical investigation and determination of some heavy metals and drugs [30][31][32][33][34][35][36]. To our knowledge there are a few reports on the simultaneous electrochemical determination of COD and AC [37].…”
Section: Introductionmentioning
confidence: 97%
“…In our previous works, we used some nanoparticles in electrochemical investigation and determination of some heavy metals and drugs [30][31][32][33][34][35][36]. To our knowledge there are a few reports on the simultaneous electrochemical determination of COD and AC [37].…”
Section: Introductionmentioning
confidence: 97%
“…The performances of the three proposed Al(III) electrodes were compared with the previously reported ones [21, 22, 28, 29, 48–52]. As shown in Table 3, the coated paste electrode showed superior response to the target cation ions over the other proposed sensors because of the wide linear range, short response time and Nernstian slope.…”
Section: Resultsmentioning
confidence: 93%
“…The (dE°/dt) cell values 1.8 × 10 À 5 -1.0 × 10 À 1 2.5-4. 5 10 [22] 19.3 2.5 × 10 À 6 1.0 × 10 À 6 -1.0 × 10 À 1 3.0-8.0 10 [28] 20.0 7.0 × 10 À 6 9.0 × 10 À 6 -1.0 × 10 À 1 2.5-4.0 9 [29] 19.8 4.6 × 10 À 7 1.0 × 10 6 -1.0 × 10 À 1 2.0-6.0 8 [48] 19.4 1.0 × 10 À 6 2.0 × 10 À 6 -2.0 × 10 À 2 3.5-5.0 5 [49] 19.2 1.6 × 10 À 7 4.5 × 10 À 7 -1.6 × 10 À 3 2.2-4.0 15 [50] 15.6 5.1 × 10 À 6 1.0 × 10 À 5 -1.5 × 10 À 2 3.5-4.5 < 10 [51] 19.0 5.5 × 10 À 7 1.0 × 10 À 6 -1.0 × 10 À 1 4.0-8.0 15 [52] 19.6 1.0 × 10 À 5 2.04 × 10 À 5 -1.99 × 10 À 1 2.0-4.0 5.0 This Work MCP 20.0 1.00 × 10 À 6 1.00 × 10 À 6 -1.00 × 10 À 2 4.5-6.5 10 PVC…”
Section: Effect Of Temperatureunclassified
“…As a result of the experimental work, cross interactions with other ions in the studied concentrations were not revealed. As for the possibility of interaction of the residues of MCA with other ions, such as aluminum, several works showed the determination of aluminum in the joint presence with copper ions [50,51]. At the same time, in the developed electrochemical systems with potentiometric detection, the same interaction of copper and aluminum ions was observed.…”
Section: Selectivity Of Fe(iii) Ion Detectionmentioning
confidence: 92%