2017
DOI: 10.1148/radiol.2017151022
|View full text |Cite
|
Sign up to set email alerts
|

Use of Volumetry for Lung Nodule Management: Theory and Practice

Abstract: A consistent feature of many lung nodule management guidelines is the recommendation to evaluate nodule size by using diameter measurements and electronic calipers. Traditionally, the use of nodule volumetry applications has primarily been reserved for certain lung cancer screening trials rather than clinical practice. However, even before the first nodule management guidelines were published more than a decade ago, research has been ongoing into the use of nodule volumetry as a means of measuring nodule size,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
140
1
11

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 128 publications
(152 citation statements)
references
References 79 publications
0
140
1
11
Order By: Relevance
“…Firstly, for masses with reduced attenuation, which are normally known as sub‐solid masses, under‐segmentation or false negatives may be observed, particularly for GGO masses. Earlier studies have described high errors of volumetric segmentation in sub‐solid nodules in comparison to solid nodules . For example, subject 054 (Figure , first column) and subject 224 (Figure , first column) consist of reduced attenuation characteristics and both suffered the issue.…”
Section: Discussionmentioning
confidence: 94%
See 2 more Smart Citations
“…Firstly, for masses with reduced attenuation, which are normally known as sub‐solid masses, under‐segmentation or false negatives may be observed, particularly for GGO masses. Earlier studies have described high errors of volumetric segmentation in sub‐solid nodules in comparison to solid nodules . For example, subject 054 (Figure , first column) and subject 224 (Figure , first column) consist of reduced attenuation characteristics and both suffered the issue.…”
Section: Discussionmentioning
confidence: 94%
“…Earlier studies have described high errors of volumetric segmentation in sub-solid nodules in comparison to solid nodules. 25,26 For example, subject 054 ( Figure 7A, first column) and subject 224 ( Figure 7B, first column) consist of reduced attenuation characteristics and both suffered the issue. Additionally, under-segmentation was also observed in one experimental case involving a mediastinal mass ( Figure 4B, first column), which was assumed to be a unique event involving the "bridging" condition.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Nodule size is most commonly measured manually using electronical calipers, with the long-and perpendicular short-axis being measured on two-dimensional images (5). As a management criterion alternative to size, three-dimensional nodule volume has been discussed in the literature (6) and has also received mention in recent management guidelines for incidental nodules (1,3).…”
mentioning
confidence: 99%
“…This causes another relevant problem, as many patients to undergo consecutive examinations on different CT scanner models operating with constantly upgraded software packages, and, potentially, in different geographical locations. Finally, one should keep in mind that automatic or semi-automatic volume measurements perform poorly in subpleural and subsolid nodules, which currently excludes a substantial number of nodules from the assessment with this technology (6).…”
mentioning
confidence: 99%