2015
DOI: 10.1007/s10840-015-0005-5
|View full text |Cite
|
Sign up to set email alerts
|

Use of vascular closure device is safe and effective in electrophysiological procedures

Abstract: We provide evidence that a collagen plug-based VCD designed for arterial closure can be safely and effectively used to close multiple venous accesses even in the same vein. This can be accomplished with a venotomy size up to 2 Fr larger than the size of the closure device.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 8 publications
0
11
0
1
Order By: Relevance
“…A suture-mediated Perclose device has been successfully used to achieve rapid hemostasis in the presence of anticoagulation in adults undergoing congenital cardiac intervention [11] . Femoral venous hemostasis has been achieved with a collagen vascular closure device (Angioseal) in patients that required peri-procedural anticoagulation and multiple vascular access sites [12] . However, these devices are resource-intense, are associated with steep learning curves, and may be associated with patient discomfort during deployment.…”
Section: Discussionmentioning
confidence: 99%
“…A suture-mediated Perclose device has been successfully used to achieve rapid hemostasis in the presence of anticoagulation in adults undergoing congenital cardiac intervention [11] . Femoral venous hemostasis has been achieved with a collagen vascular closure device (Angioseal) in patients that required peri-procedural anticoagulation and multiple vascular access sites [12] . However, these devices are resource-intense, are associated with steep learning curves, and may be associated with patient discomfort during deployment.…”
Section: Discussionmentioning
confidence: 99%
“…thromboembolism. [17][18][19][20][21][22] Coto et al studied the use of an 8 Fr AngioSeal device for femoral venous closure and venous hemostasis was successfully achieved; however, 8% of patients had bleeding due to ipsilateral arterial access. 23 A study by Maraj et al on a small number of patients found the use of AngioSeal to be effective in closing multiple venous access on the same vein without reported device dislodgements.…”
Section: Discussionmentioning
confidence: 99%
“…23 A study by Maraj et al on a small number of patients found the use of AngioSeal to be effective in closing multiple venous access on the same vein without reported device dislodgements. 19 attributed to inadequate knot tie or suture break. 4,6 A modified F8 suture, where a three-way stopcock is utilized instead of knots, was evaluated by Yorgun et al In comparison to the standard F8 suture, the use of the modified F8 resulted in a shorter time to hemostasis with no documented minor or major access site complication.…”
Section: Discussionmentioning
confidence: 99%
“…The use of some VCDs for femoral venous closure has been reported, mainly from small retrospective studies (summarised in table 1) [6][7][8][9][10][11][12][13][14][15]. Coto, et al, (2002) studied the use of AngioSeal (St Jude) to close the common femoral vein in 110 patients undergoing cardiac catheterisation or intervention requiring venous access, demonstrating 100% successful deployment and haemostasis without complication [6].…”
Section: Introductionmentioning
confidence: 99%