2018
DOI: 10.20944/preprints201808.0351.v1
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Use of Transient Time Response as a Measure to Characterize Phononic Crystal Sensors

Abstract: Phononic crystals are periodic composite structures with specific resonant features that are gaining strength in the field as liquid sensors. The introduction of a structural defect in an otherwise periodic regular arrangement can generate a resonant mode, also called defect mode, inside the characteristic band gaps of phononic crystals. The morphology, as well as the frequency in which these defect modes appear, can give useful information on the composition and properties of an analyte. Currently, only gain,… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 22 publications
(29 reference statements)
0
2
0
Order By: Relevance
“…It is seen that the 1D-DPC gas sensor has sensitivity values of 292, 207, 202, and 103 MHz/(kg/m 3 ) for O 2 , NH 3 , CO 2 , and CH 4 gases, respectively. Moreover, our proposed 1D-DPC can be implemented experimentally and theoretically easily due to the use of 1D multilayered structures in sensing applications that were introduced in several works of literature 43,[52][53][54][55] . This work is a full theoretical and simulation investigation.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is seen that the 1D-DPC gas sensor has sensitivity values of 292, 207, 202, and 103 MHz/(kg/m 3 ) for O 2 , NH 3 , CO 2 , and CH 4 gases, respectively. Moreover, our proposed 1D-DPC can be implemented experimentally and theoretically easily due to the use of 1D multilayered structures in sensing applications that were introduced in several works of literature 43,[52][53][54][55] . This work is a full theoretical and simulation investigation.…”
Section: Methodsmentioning
confidence: 99%
“…This work is a full theoretical and simulation investigation. However, the proposed design can easily be experimentally fabricated similar to identical 1D-PCs structures such as those listed in the past articles 26 , 54 . Also, our study of the 1D-PC as a gas sensor based on the TMM through MATLAB program as described in detail in the theoretical model.…”
Section: Methodsmentioning
confidence: 99%