2019
DOI: 10.1111/iej.13242
|View full text |Cite
|
Sign up to set email alerts
|

Use of the metal artefact reduction tool in the identification of fractured endodontic instruments in cone‐beam computed tomography

Abstract: Aim To evaluate the influence of the metal artefact reduction (MAR) tool in the diagnosis of fractured instruments in root canals of extracted mandibular molars, with or without root canal fillings. Methodology The root canals of 31 mandibular molars were divided into four groups: (i) the control group, without root fillings; (ii) the fracture group, without fillings and with fractured files; (iii) the fill group, with root filling; and (iv) the fill/fracture group, root filled and with fractured files. The fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0
4

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(19 citation statements)
references
References 17 publications
(44 reference statements)
0
15
0
4
Order By: Relevance
“…No significant differences in presence of artifacts were found in the comparison of protocols. The influence of the metal artifact reduction (MAR) tool using two scanners, in the diagnosis of fractured instruments in root canals of mandibular molars with or without canal fillings, was determined recently (34). The MAR tool did not increase the detection of fractured endodontic instruments or reduce image noise.…”
Section: Blooming Artifact Reduction With New Cbct Softwarementioning
confidence: 99%
See 1 more Smart Citation
“…No significant differences in presence of artifacts were found in the comparison of protocols. The influence of the metal artifact reduction (MAR) tool using two scanners, in the diagnosis of fractured instruments in root canals of mandibular molars with or without canal fillings, was determined recently (34). The MAR tool did not increase the detection of fractured endodontic instruments or reduce image noise.…”
Section: Blooming Artifact Reduction With New Cbct Softwarementioning
confidence: 99%
“…The MAR tool did not increase the detection of fractured endodontic instruments or reduce image noise. Therefore, the MAR tool was not recommended for evaluations of fractured endodontic instruments in mandibular molars with or without root fillings (34). Pauwels et al (35) discussed important principles of image acquisition and reconstruction.…”
Section: Blooming Artifact Reduction With New Cbct Softwarementioning
confidence: 99%
“…Los nuevos estudios demuestran que, por causa de la prevalencia de la distorsión geométrica, la radiografía convencional ofrece un valor limitado en los tratamientos de conductos complejos, lo que lleva al clínico a la obtención de imágenes proporcionadas por una resolución espacial en todos los planos, hoy en día disponible en la tomografía computarizada de haz cónico (TCHC), que proporciona imágenes en 3D que disminuyen el campo de visión (FOV) y aumentan la precisión de la imagen radiográfica ( [1][2][3][4][5][6][7][8][9][10][11] ).…”
Section: Introductionunclassified
“…La radiología oral está en constante evolución, lo que obliga al clínico a una actualización de sus conocimientos básicos en imagenología. El uso de las TCHC para el dominio y reconocimiento del sistema de conductos radiculares resulta necesario en aquellos casos de abordaje complejo como lesiones postrauma, fracturas radiculares, reabsorciones, fracturas de postes, instrumentos fracturados, calcificaciones radiculares, así como para la planificación y ejecución de cirugías paraendodónticas ( 1,5,7,(10)(11)(12)(13)(14)(15) ).…”
Section: Introductionunclassified
See 1 more Smart Citation