2016
DOI: 10.1016/j.jcms.2016.04.008
|View full text |Cite
|
Sign up to set email alerts
|

Use of the Delta plate for surgical treatment of patients with condylar fractures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
29
0
4

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(37 citation statements)
references
References 34 publications
4
29
0
4
Order By: Relevance
“…Our experience indicates that this procedure requires careful surgery with careful blunt dissection of the soft tissue layers including parotid capsule so that the nerve can be protected and retracted, and also avoid prolonged traction on the operated site. However, Sikora et al 25 in their study diagnosed 7% of the patients during the postoperative period with a partial paresis of the facial nerve; in each of these cases, the correct function of the facial nerve returned spontaneously 3 months after the surgery.…”
Section: Discussionmentioning
confidence: 91%
See 1 more Smart Citation
“…Our experience indicates that this procedure requires careful surgery with careful blunt dissection of the soft tissue layers including parotid capsule so that the nerve can be protected and retracted, and also avoid prolonged traction on the operated site. However, Sikora et al 25 in their study diagnosed 7% of the patients during the postoperative period with a partial paresis of the facial nerve; in each of these cases, the correct function of the facial nerve returned spontaneously 3 months after the surgery.…”
Section: Discussionmentioning
confidence: 91%
“…Sikora et al 25 The mean maximal interincisal opening postoperatively was 43.67 mm (range 38 to 48mm with SD 2.74 mm). This value is consistent with the results of Landes et al 28.…”
Section: Discussionmentioning
confidence: 94%
“…Insofern ist eine Pseudarthrosenbildung nach konservativer Versorgung somit funktionell eher als ein sogar erwünschter Kompensationsmechanismus zu verstehen. Im Gegensatz dazu wirkt sich einin dieser biomechanisch anspruchsvollen Frakturregion [6,20,21] nicht seltenes -Osteosyntheseversagen, z. B. bei Einsatz von einzelnen oder zu gering dimensionierten Miniplatten (vgl.…”
Section: Pseudarthrosen Bei Gelenkfortsatzfrakturenunclassified
“…Für Materiallockerungen besonders anfällig sind Gelenkhals-oder bilaterale Frakturen, z. B. bei fehlender okklusaler Abstützung [21]. Durch gelockertes Osteosynthesematerial kann es zu ausgeprägten Osteolysen mit Destruktion des Unterkieferastes bzw.…”
Section: Pseudarthrosen Bei Gelenkfortsatzfrakturenunclassified
“…The literature presents results in both experimental and clinical studies using 3D plates [97,106,107,108,109,110,111,112,113,114,115,116,117,118]. Their advantage over conventional Also Kim et al argue that using biodegradable plates is a stable and reliable method for the management of mandibular subcondylar fractures and eliminates the need for secondary surgery for plate removal [128].…”
Section: The Choice Of Surgical Approach For the Open Treatment Of Comentioning