Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience

Abstract: The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Günther tulip filters were used as retrievable filters. The fr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 68 publications
(34 citation statements)
references
References 26 publications
0
34
0
Order By: Relevance
“…Another cause is inability to engage the filter apex with the Recovery Cone [4], although alternative retrieval techniques have been successfully employed [14][15][16]. Struts that have embolized may be left in place if asymptomatic and not at risk for causing additional injury [17], or they may be retrieved percutaneously [18]. In the rare event a filter embolizes to the heart, they may be removed percutaneously [19,20] if experienced operators are available and patients have high surgical risk, although they generally require surgical removal [17].…”
Section: Discussionmentioning
confidence: 99%
“…Another cause is inability to engage the filter apex with the Recovery Cone [4], although alternative retrieval techniques have been successfully employed [14][15][16]. Struts that have embolized may be left in place if asymptomatic and not at risk for causing additional injury [17], or they may be retrieved percutaneously [18]. In the rare event a filter embolizes to the heart, they may be removed percutaneously [19,20] if experienced operators are available and patients have high surgical risk, although they generally require surgical removal [17].…”
Section: Discussionmentioning
confidence: 99%
“…Its retrieval hook is caudal, warranting a femoral snare approach. These devices are inserted and removed safely with a high degree of technical success [2,5,50,52,[57][58][59][60][61].…”
Section: Ivc Filters and Dwell Timesmentioning
confidence: 99%
“…Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters [1][2][3]. In parallel, the complications of long-or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public [4][5][6][7][8][9][10][11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations