1993
DOI: 10.1097/00003086-199301000-00029
|View full text |Cite
|
Sign up to set email alerts
|

Use of Pulsed Electromagnetic Fields in Treatment of Loosened Cemented Hip Prostheses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0
1

Year Published

1996
1996
2013
2013

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 0 publications
0
13
0
1
Order By: Relevance
“…Although the vast majority of electrical stimulation usage in orthopaedics has centered around fracture healing applications, several attempts have been made to improve the success of total joint replacements (TJR). Ten year total hip arthroplasty (THA) follow‐up studies have reported symptomatic loosening which require revision in 1.2–12% of patients for the acetabulum and between 3 and 20% for the femoral component 91. It has also been well documented that bone loss as large as 14% may occur in the first 3 months following THA 92.…”
Section: Application Of Bioelectricity In Orthopaedicsmentioning
confidence: 99%
See 1 more Smart Citation
“…Although the vast majority of electrical stimulation usage in orthopaedics has centered around fracture healing applications, several attempts have been made to improve the success of total joint replacements (TJR). Ten year total hip arthroplasty (THA) follow‐up studies have reported symptomatic loosening which require revision in 1.2–12% of patients for the acetabulum and between 3 and 20% for the femoral component 91. It has also been well documented that bone loss as large as 14% may occur in the first 3 months following THA 92.…”
Section: Application Of Bioelectricity In Orthopaedicsmentioning
confidence: 99%
“…Dallari et al92 used a single voltage pulsed at 75 Hz, with each burst lasting 1.3 ms and a magnetic field 2 ± 0.2 mT whereas Steinberg95 used a 15 Hz pulsing rate with each burst containing 32 pulses inducing a current of 5–20 μA/cm 2 . The inconsistencies in PEMF treatment and dosage have lead many researchers to conclude that electrical stimulation may be useful for delaying the time when a THA may be necessary, but will not improve the longevity of the TJR 91…”
Section: Application Of Bioelectricity In Orthopaedicsmentioning
confidence: 99%
“…(Tables 3, 4 and 5) There were a few problems in the studies that set their outcome as the completion time of bone union or wound healing. However, even when there was a positive effect at 6 months, as in the prevention of the loosening of an arti®cial joint [Kennedy et al, 1993], the result had no clinical relevance when its clinical ®nding was aggravated 14 months or 3 years later. In cases when each datum itself was a quantitative one, there were still problems, such as inability to combine the degrees of knee extension lag, hospital stay [Gotlin et al, 1994], and the knee pain scores [Zizic et al,1995].…”
Section: Quality Assessmentmentioning
confidence: 99%
“…Although this heating effect is small, some enzymes are exquisitely sensitive to small variations in temperature [54]. It was reported that 0.24 W/cm 2 pulsed shortwave diathermy was safe for human with titanium implants [28,55], and 0.5 W/cm 2 continuous microwave could produce thermal effect on fracture rehabilitation in rabbit [15,16]. In the present study, the effective treatment area of the applicator we used was 138.9 cm 2 and the dose of continuous microwave was 0.18 W/cm 2 , which derived from a randomized clinical trial of microwave stimulation of bone healing we did previously.…”
Section: Discussionmentioning
confidence: 99%